Welcome back to Air Quality Matters and one take, one take my take on a paper or report on air quality, ventilation and the built environment.

2
00:00:22.527 --> 00:00:27.611
And another report on schools this week, although a little bit of a twist, slightly different from last week.

3
00:00:28.111 --> 00:00:37.498
I'm Simon Jones and today we're heading over to Spain to unpack a study that deals with one of the most frustrating, common and complex indoor environments.

4
00:00:37.679 --> 00:00:40.301
We have to manage the primary school classroom.

5
00:00:40.921 --> 00:00:53.006
It's a study published in Atmospheric Pollution Research titled Effects of Classroom Ventilation Management and User Activities on Indoor Air Quality in Madrid Primary Schools, a two year field study.

6
00:00:53.606 --> 00:01:00.088
Now, if you want to understand why air quality in schools is such a massive headache, you have to look at the sheer numbers.

7
00:01:00.608 --> 00:01:08.231
In a typical office building, we might design for an occupancy density of one person per 10 or 15 square metres.

8
00:01:08.851 --> 00:01:10.292
In a primary school classroom,

9
00:01:10.642 --> 00:01:16.947
you are packing 30 active, fast-breathing children into a space of maybe 50 square meters.

10
00:01:17.507 --> 00:01:21.690
That's an occupancy density of less than 2 square meters per person.

11
00:01:22.211 --> 00:01:25.653
On top of that, children are not just little adults.

12
00:01:26.174 --> 00:01:34.140
Their metabolic rates are higher, they breathe more, air relative to their body weight, and their lungs are still actively developing.

13
00:01:34.780 --> 00:01:38.243
Yet, across Europe, and particularly in Southern Europe,

14
00:01:38.584 --> 00:01:44.150
the vast majority of these high-density classrooms rely entirely on natural ventilation.

15
00:01:45.571 --> 00:01:55.722
That means the only thing standing between those kids and a mountain of stale, polluted air is a teacher physically walking over to a window and opening it.

16
00:01:56.373 --> 00:02:02.334
This Madrid study wanted to see if we could solve this problem through behavioral management alone.

17
00:02:03.094 --> 00:02:08.816
They set up a two-year field study monitoring nine classrooms across four primary schools.

18
00:02:09.556 --> 00:02:12.997
During the first year, 2024, they just watched.

19
00:02:13.577 --> 00:02:23.399
They recorded business as usual, teachers and students opening and closing windows and doors completely freely based on whether they felt hot, cold or stuffy.

20
00:02:24.595 --> 00:02:28.797
Then in the second year, 2025, they intervened.

21
00:02:29.698 --> 00:02:39.944
They implemented a structured seasonal adapted manual ventilation protocol in one classroom per school, using the other classrooms as controls.

22
00:02:40.804 --> 00:02:45.087
This protocol wasn't just a generic leave the windows open sign.

23
00:02:45.367 --> 00:02:46.628
It was highly detailed.

24
00:02:47.368 --> 00:02:56.476
It scheduled specific window and door openings, such as five minutes at the start of the classroom, during every recess and during lunch breaks.

25
00:02:56.856 --> 00:03:05.703
And it adapted the width of the window opening based on whether it was freezing winter, mid-season or a warm spring afternoon.

26
00:03:06.464 --> 00:03:14.911
They measured a whole suite of parameters, carbon dioxide, temperature, relative humidity, total volatile organic compounds and PM10.

27
00:03:17.441 --> 00:03:28.585
But before we look at what they found, let's critique the methodology because there are some weaknesses here and that we need to talk about if we're going to apply these findings to the real world.

28
00:03:29.985 --> 00:03:32.426
First, the sample size is incredibly small.

29
00:03:32.786 --> 00:03:36.608
Nine classrooms across four schools in a city like Madrid.

30
00:03:37.108 --> 00:03:39.949
School buildings vary wildly like many cities.

31
00:03:40.549 --> 00:03:47.033
They have old drafty brick buildings from the mid 20th century and modern tightly sealed concrete structures.

32
00:03:47.853 --> 00:03:53.877
You have schools situated right next to major multi-lane highways and others in quiet leafy suburbs.

33
00:03:54.577 --> 00:04:07.705
By using such a small sample size, the local microclimate, the specific building orientation and the wind exposure of these individual classrooms becomes a massive confounding variable that are almost impossible to control.

34
00:04:08.745 --> 00:04:14.990
Second, the researchers did not directly measure the air change rate or air changes per hour.

35
00:04:15.430 --> 00:04:21.375
Instead, they relied entirely on indoor CO2 concentrations as a proxy for ventilation rates.

36
00:04:22.376 --> 00:04:26.819
Now we use CO2 as a proxy all the time, but it's a tricky beast.

37
00:04:27.359 --> 00:04:31.702
CO2 concentration is not a direct measurement of fresh air.

38
00:04:32.203 --> 00:04:38.387
It is a balance between the rate of fresh air coming in and the rate of CO2 being produced by the occupants.

39
00:04:39.468 --> 00:04:43.671
If the kids are sitting quietly reading, their CO2 production could be quite low.

40
00:04:44.291 --> 00:04:51.196
If they're singing, shouting and doing active exercises, remember this is primary schools, their CO2 production spikes.

41
00:04:52.275 --> 00:05:01.881
Without a direct tracer gas decay test or active airflow measurements relying purely on CO2 concentration introduces a high degree of uncertainty.

42
00:05:03.262 --> 00:05:08.045
But the biggest weakness of all, and the authors admit this, is the human factor.

43
00:05:08.726 --> 00:05:13.009
A manual ventilation protocol is only as good as the people executing it.

44
00:05:13.769 --> 00:05:15.030
And what did they find?

45
00:05:16.241 --> 00:05:18.262
Compliance was highly erratic.

46
00:05:18.783 --> 00:05:26.408
In the dead of winter, teachers simply refused to open the windows because the cold drafts were unbearable, which is completely understandable.

47
00:05:27.189 --> 00:05:34.113
During exams or quiet study periods, windows stayed closed because the outdoor street noise was too distracting.

48
00:05:35.034 --> 00:05:40.778
If a teacher was in the middle of a complex, engaging lesson, they forgot about the post-cold entirely.

49
00:05:42.330 --> 00:05:53.115
We are essentially asking teachers to be human EVAC controllers, managing drafts, noise, security and air quality, all while trying to teach 30 young children.

50
00:05:54.215 --> 00:05:59.578
It is a fragile, unstable and unsustainable way to manage a building.

51
00:06:00.220 --> 00:06:07.148
Now let's look at the actual data because despite these limitations, the results are really interesting.

52
00:06:07.708 --> 00:06:13.234
When it came to carbon dioxide, the relationship with occupancy and window opening was stark.

53
00:06:14.170 --> 00:06:25.859
During lessons with closed windows, CO2 built up at an alarming rate, frequently soaring well past 1500 parts per million and even 2000 parts per million within 30 minutes.

54
00:06:26.940 --> 00:06:32.004
When the schedule breaks arrived and the windows were opened, levels dropped rapidly.

55
00:06:32.864 --> 00:06:34.486
Did the structure protocol help?

56
00:06:34.926 --> 00:06:35.927
Yes, it did.

57
00:06:36.327 --> 00:06:42.792
The intervention classrooms had generally lower average CO2 levels than the business as usual classrooms.

58
00:06:43.437 --> 00:06:53.905
But, and this is a massive but, even with strict compliance, they still recorded major CO2 spikes during long, densely occupied teaching blocks.

59
00:06:55.206 --> 00:07:02.051
It proved that in high-density classrooms, manual natural ventilation simply cannot keep up.

60
00:07:02.592 --> 00:07:10.118
Passive window opening has physical limits, especially when wind speeds are low or outdoor temperatures are extreme.

61
00:07:11.055 --> 00:07:19.837
The findings for TVOCs and PM10 were even more complex and heterogeneous, and this is where you have to look beyond simple ventilation.

62
00:07:20.737 --> 00:07:25.818
They found that TVOC concentrations did not correlate with CO2 occupancy at all.

63
00:07:26.178 --> 00:07:35.220
Instead, TVOCs showed massive sudden spikes that coincided with specific activities, which when you think about it is not a surprise.

64
00:07:35.840 --> 00:07:48.605
We're talking about arts and crafts sessions, using solvent based glues, permanent markers and paints, or intense cleaning activities during breaks when staff use chlorine based bleaches or alcohol sanitizers.

65
00:07:49.966 --> 00:07:52.627
This is a critical lesson for the built environment.

66
00:07:53.027 --> 00:07:58.669
Dilution is the cure for pollution, is a failed mindset if you ignore source control.

67
00:07:59.610 --> 00:08:04.612
If we're packing a classroom with high emitting synthetic materials and chemical cleaning products,

68
00:08:04.992 --> 00:08:09.193
No amount of window opening is going to keep those kids safe from chemical exposure.

69
00:08:10.994 --> 00:08:16.995
For PM10, the larger particulate matter, the spikes were almost entirely driven by physical movement.

70
00:08:17.555 --> 00:08:23.737
When the kids were active, playing games, dancing or moving furniture, PM10 shot up dramatically.

71
00:08:24.537 --> 00:08:28.558
This wasn't because of a lack of ventilation, it was due to resuspension or dust.

72
00:08:29.538 --> 00:08:32.779
Over time, dust, skin, flakes and textile fibres were...

73
00:08:33.232 --> 00:08:37.734
and outdoor dirt track in with shoes and settle on classroom floors and carpets.

74
00:08:38.274 --> 00:08:45.698
The physical activity of 30 children acts like a giant fan, kicking these settled particles back up into the breathing zone.

75
00:08:47.313 --> 00:09:00.938
Worse still, the researchers found that opening windows sometimes increased PM10 levels inside classrooms, especially in schools located near busy roads, as outdoor traffic soot and urban dust drifted straight into the room.

76
00:09:00.958 --> 00:09:03.959
And we've seen this pattern repeated in many, many other studies.

77
00:09:05.759 --> 00:09:08.400
So what are the wider parallels we can draw here?

78
00:09:09.321 --> 00:09:16.143
The study exposes the absolute fallacy of relying on behavioural changes to solve structural engineering deficits.

79
00:09:17.110 --> 00:09:25.652
Asking teachers and students to manage natural ventilation is a stopgap measure at best and a recipe for failure at worst.

80
00:09:26.412 --> 00:09:37.515
It creates a constant battle between thermal comfort, acoustic distraction, energy waste and clean air and frankly, the hundred other battles a teacher might be fighting at any one time.

81
00:09:38.485 --> 00:09:47.794
If you're serious about protecting health and wellbeing and cognitive performance of our children, we must stop treating mechanical ventilation as an optional luxury.

82
00:09:48.941 --> 00:09:58.384
We, you, need continuous automated mechanical ventilation with heat recovery, ideally coupled with high efficient particulate filtration.

83
00:09:59.064 --> 00:10:12.969
This takes the burden entirely off the teacher, keeps the outdoor pollutants out and saves energy and ensures that every single child has access to clean, healthy air every single second of the school day.

84
00:10:14.743 --> 00:10:15.804
Thanks as always for listening.

85
00:10:15.904 --> 00:10:19.607
I do appreciate you spending time with me and do check out our sponsors in the show notes.

86
00:10:19.867 --> 00:10:28.233
This podcast is brought to you in partnership with Safe Traces, Imbiate, Farmwood, Zender, EI Electronics and the IAIR Institute.

87
00:10:28.533 --> 00:10:32.416
All great companies who share the passion for this podcast and aren't here by accident.

88
00:10:33.056 --> 00:10:35.778
Your support of them helps them support this show.

89
00:10:36.059 --> 00:10:36.599
Thanks a million.

90
00:10:36.739 --> 00:10:37.740
And I'll see you again next week.