WEBVTT

1
00:00:00.507 --> 00:00:02.449
Welcome back to Air Quality Matters.

2
00:00:02.829 --> 00:00:08.874
I'm Simon Jones and coming up a conversation with Rebecca Coates, Head of Radon Projects at Property Co.

3
00:00:09.655 --> 00:00:24.188
Since co-founding the company in 2011, Rebecca has managed radon testing and mitigation programs across the sector, including for major clients like high street retailers, banks and hotel chains.

4
00:00:25.353 --> 00:00:41.326
Rebecca has become one of the UK's leading communicators on the subject of radon, and she has sat on the board of the UK Radon Association since its inception and was a member of the European Radon Association's Executive Committee from 2015 to 2021.

5
00:00:44.638 --> 00:00:58.483
Rebecca's expertise has been called upon regularly by external organisations and she's been involved in policy consultations regarding radon with the UK Health Security Agency, building research establishment and much more.

6
00:00:59.583 --> 00:01:13.788
What's clear, though, from speaking with Rebecca is her down to earth communication approach to radon, a problem we are discussing this autumn in a series of podcasts with this episode going out on Radon Awareness Week in the UK.

7
00:01:14.838 --> 00:01:24.882
The UK Radon Association is launching a targeted campaign across five locations to highlight the continuing knowledge gap surrounding radon.

8
00:01:25.602 --> 00:01:30.224
And this is a fantastic plain English conversation about what happens next.

9
00:01:30.484 --> 00:01:34.346
What does radon mitigation actually look like for a homeowner?

10
00:01:34.606 --> 00:01:37.587
And frankly, I learned a lot from this conversation too.

11
00:01:38.327 --> 00:01:45.371
Radon work on homes and their service and upkeep should be as common and well understood as getting your boiler done.

12
00:01:46.131 --> 00:01:51.514
Yet ask the person in the street what radon is, never mind how you fix it.

13
00:01:51.795 --> 00:01:55.276
And in far too many cases, they simply have not a clue.

14
00:01:55.797 --> 00:02:01.240
And honestly, I can't think of a better person to have sat down with to talk about this challenge.

15
00:02:02.252 --> 00:02:03.993
Loads in this one, so enjoy.

16
00:02:04.253 --> 00:02:14.140
And if you haven't checked out the podcast from a couple of weeks ago on radon testing and want to catch up with others this autumn on the topic, don't forget to subscribe.

17
00:02:14.820 --> 00:02:26.568
This podcast is brought to you in partnership with Man Hummel, Particles Plus, Eiko, Eurovent, Lindab and S&amp;P Ventilation, along with our charity partners, The Safer Air Project.

18
00:02:27.368 --> 00:02:30.371
These podcasts simply would not be possible without them.

19
00:02:30.691 --> 00:02:34.795
Please do check them out in the show notes and at airqualitymatters.net.

20
00:02:35.196 --> 00:02:38.459
This is a conversation with Rebecca Coates.

21
00:02:53.578 --> 00:03:03.620
Like a lot of these things, we say remediation and it can mean lots of different things in different parts of the world and with different pollutants.

22
00:03:03.960 --> 00:03:07.081
And I was only thinking about this, actually, this morning.

23
00:03:07.701 --> 00:03:14.943
You know, often when we talk about mould remediation or remediation because of a pollutant spill of some description, it's...

24
00:03:16.744 --> 00:03:21.989
or because meth has been created on a property.

25
00:03:22.610 --> 00:03:30.437
Often there's residual issues to deal with, with a lot of pollution when we talk about remediation, but we don't really have that problem with radon.

26
00:03:30.457 --> 00:03:31.658
It's not like radon...

27
00:03:33.697 --> 00:03:54.727
seeps into the the fabric and then you're you're left with having to pull plasterboard off the wall because radon's been in you know it's in that way you're quite there's no contamination from it it just isn't yeah and once the radon's not in the air as long as you keep that um as the status quo going forward then yeah you're dealing with your problem

28
00:03:55.554 --> 00:03:55.734
Yeah.

29
00:03:55.874 --> 00:04:01.740
And I know in some parts of the world, they've had problems with building materials actually having the radon in it.

30
00:04:01.800 --> 00:04:07.486
So it's not to say it can't come out of the walls and your kitchen worktops and various other different sources.

31
00:04:07.646 --> 00:04:14.993
But in the world of remediation, it's probably one of the easier ones in the sense that it's just the gas.

32
00:04:15.013 --> 00:04:17.836
And when we get rid of the gas, we've dealt with the problem largely.

33
00:04:17.936 --> 00:04:18.156
Right.

34
00:04:18.677 --> 00:04:18.857
Yeah.

35
00:04:19.057 --> 00:04:19.958
Usually that is the case.

36
00:04:21.771 --> 00:04:35.306
So when you're talking to a layperson that asks you what you do, or you're trying to describe what remediation is in its simplest form, how do you kind of describe what that process is?

37
00:04:36.376 --> 00:04:49.119
So we talk about it in terms of managing the pressure difference between the ground and the building, because that's how radon gets inside a building, because we have lower air pressure in the building than in the ground.

38
00:04:49.319 --> 00:04:59.081
So it's a process called advection which is occurring, which is a fancy way of saying the gas is moving from a point of high pressure, the ground, into a point of low pressure which is usually the building.

39
00:04:59.761 --> 00:05:21.222
So to deal with radon mitigation in an existing building, rather than trying to have a physical barrier, which is fairly impossible to get to be airtight in an existing building, we actually manage where the gas is drawn or where the gas wants to go towards and try and make the house or the building, whatever type of building we're dealing with, make that the least attractive pathway that the gas can take.

40
00:05:21.842 --> 00:05:32.837
So we're doing that by either creating a point of low pressure somewhere else, which is not the house or the building, or we're very slightly increasing the pressure in the building.

41
00:05:33.298 --> 00:05:38.345
So that doesn't become an attractive pathway or natural pathway for the gas to take from the ground.

42
00:05:39.194 --> 00:05:54.790
Yeah, so what you've described there really is the kind of the science or scientific approach of radon being a gas problem and effectively trying to stop it coming in the home.

43
00:05:55.210 --> 00:05:56.191
Principally, that's...

44
00:05:56.852 --> 00:05:57.453
the idea.

45
00:05:59.475 --> 00:06:00.636
What does that look like?

46
00:06:01.096 --> 00:06:06.442
You say that to somebody and say, look, what we're trying to do is gas is a, you know, radon gas is a problem.

47
00:06:07.042 --> 00:06:09.104
The trick is to get it out of the property.

48
00:06:09.144 --> 00:06:11.447
We can't change it to make it safer.

49
00:06:11.527 --> 00:06:12.828
We've just got to stop it getting in.

50
00:06:13.088 --> 00:06:14.410
We've done that by either...

51
00:06:15.010 --> 00:06:20.399
decreasing the pressure under the house or increasing the pressure slightly above the in the house or both.

52
00:06:21.821 --> 00:06:24.084
And they go, great, that sounds fantastic.

53
00:06:24.265 --> 00:06:24.886
What does that mean?

54
00:06:26.368 --> 00:06:30.234
So practically, how do we do that to a property?

55
00:06:30.758 --> 00:06:35.781
Yeah, so the good news is it's not hugely disruptive work that has to be done to a building.

56
00:06:36.441 --> 00:06:41.404
When we come in and we talk about this being retrofit work, so we're doing it after the building is complete.

57
00:06:41.504 --> 00:06:52.110
So the most successful option usually is to use something which we call a radon sump, which this is to do with creating a point of low pressure beneath the building.

58
00:06:52.490 --> 00:06:55.512
So within the ground, we usually from outside the building,

59
00:06:56.332 --> 00:06:59.674
We, with a diamond cord drill, cord drill a hole, dig down a little bit.

60
00:06:59.714 --> 00:07:05.338
So whether that be on the flower bed or a path or some paving slabs, lift those up.

61
00:07:05.358 --> 00:07:15.905
So we get down to beneath the foundations level of the building, cord drill under and excavate a small amount of the fill, usually about a bucket full worth.

62
00:07:16.005 --> 00:07:24.270
And the point of that is just to create a void, a point of low pressure to which the gas will automatically be drawn towards because gas moves from point of

63
00:07:25.151 --> 00:07:31.757
high pressure to low pressure as we previously talked about, the gas will be drawn towards there rather than upwards into the building.

64
00:07:32.277 --> 00:07:42.386
And then from there we attach some pipework which looks, to all intents and purposes, like drain pipe and rainwater goods which comes out of the sump and then up the side of the building.

65
00:07:43.027 --> 00:07:47.311
That would usually almost always pass through a radon sump fan

66
00:07:47.751 --> 00:07:51.753
which is an inline fan, so it's about a football shaped size fan.

67
00:07:52.313 --> 00:08:00.858
Pipework passes through the centre of that, that is drawing the gas out from the radon sump and then discharging it well away from any opening doors or windows in the building.

68
00:08:01.758 --> 00:08:03.979
So normally that would be above Eve's level.

69
00:08:04.579 --> 00:08:09.202
If it was on a house, if it was on a large building or industrial building, it could be on

70
00:08:09.782 --> 00:08:13.125
a gable end or somewhere where there aren't any opening doors or windows.

71
00:08:13.725 --> 00:08:23.992
And what that is doing is it is capturing the gas that's in the ground beneath the plot of land that that building's on, making sure it goes to where we want it to go, i.e.

72
00:08:24.073 --> 00:08:32.739
not up through the floors into the building, and then we are diverting that off to a safe location away from where occupants are going to be breathing it in.

73
00:08:33.912 --> 00:08:34.592
That's interesting.

74
00:08:34.893 --> 00:08:44.978
So just to kind of step back a little bit there, when you talk about a sump, I mean, a lot of people and I remember visualising this when I first heard it.

75
00:08:44.998 --> 00:08:51.722
And I don't know whether it was because I saw a drawing once or because I have a vision of what sumps look like in new builds.

76
00:08:52.262 --> 00:08:58.245
But this isn't digging up the centre of the floor of your house and running pipes to the outside.

77
00:08:58.265 --> 00:09:01.447
This is actually all done from outside of the building.

78
00:09:01.872 --> 00:09:02.272
Exactly.

79
00:09:02.312 --> 00:09:19.247
So in a new build, if you were designing a building in a radon affected area and you knew you had to design some sort of radon protection into that, then yes, you would put in what's called a sump box, which is a proprietary piece of material, a bit like an old fashioned milk crate, plastic box perforated around the sides.

80
00:09:19.748 --> 00:09:24.232
And you would put them as centrally as you could with pipework connected to then be kept off.

81
00:09:24.612 --> 00:09:28.497
outside the building ready to be connected to a fan if needed.

82
00:09:29.379 --> 00:09:37.850
In an existing building it's not practical to do that to start tearing up people's floors and almost all the time it's not necessary.

83
00:09:38.431 --> 00:09:40.994
We can reach most parts of the building footprint

84
00:09:41.855 --> 00:09:43.236
simply by coming in from outside.

85
00:09:43.256 --> 00:09:55.300
We call it a mini sump, a retrofit mini sump when we come down from outside and dig under, purely because we're not putting in a big sump box with pipework attached across all areas of the footprint of the floor.

86
00:09:55.601 --> 00:09:58.682
But there's nothing mini about its efficacy.

87
00:09:59.122 --> 00:10:09.066
Almost always they work for most standard size residential properties, one of those as long as it's sited in an appropriate position according to where the highest levels of badeon in the building are.

88
00:10:09.706 --> 00:10:37.244
and then that can be effective and reduce your radon concentrations across the whole building really interesting yeah and i think that's probably one of the most common tropes of radon remediation if people have thought about it is this idea of a sump having to going under the floor is that oh my god what am i going to do i've only just laid the kitchen stroke bathroom stroke floor tiles etc etc that that's not the case so so practically then

89
00:10:38.233 --> 00:10:47.496
You were describing a couple of approaches from the outside, that one being just core drilling with a, what, I guess a four inch kind of hundred mil type core drill, is it?

90
00:10:47.836 --> 00:11:00.040
Straight down under the foundations or actually physically digging out if it's a bed or slabs or something, a bit of manual work basically to dig down below the foundations.

91
00:11:00.080 --> 00:11:00.600
To provide the access.

92
00:11:00.720 --> 00:11:06.003
Yeah, because the drill rig can be quite long, depending how thick the walls are, how far through we have to go.

93
00:11:06.023 --> 00:11:09.684
You have to obviously be able to get down and then have the drill horizontally to go in.

94
00:11:10.405 --> 00:11:16.567
So that's why there can be a little bit of groundwork outside, but nothing that's too disruptive and nothing that can't be put back.

95
00:11:16.888 --> 00:11:17.208
Exactly.

96
00:11:17.228 --> 00:11:17.448
Yeah.

97
00:11:17.868 --> 00:11:20.570
And nothing a ground worker can't do in their sleep.

98
00:11:20.630 --> 00:11:29.938
I mean, it's very basic kind of digging, trench, drilling type work, as long as you're not drilling through services and cables and things like that.

99
00:11:29.958 --> 00:11:34.883
But that's all basic rudimentary surveying before you start drilling.

100
00:11:35.603 --> 00:11:42.149
Now, you know, if you kind of think of the structure of an external wall, you have the wall that you can see.

101
00:11:42.349 --> 00:11:45.612
You'll have the wall as it disappears into the ground level.

102
00:11:46.492 --> 00:11:50.215
below usually the damp, coarse membrane, if it has one.

103
00:11:50.915 --> 00:11:56.259
And then there's often some kind of a foundation, depending on the age of the building, that's going to differ quite a bit.

104
00:11:56.319 --> 00:12:03.544
But worst case scenario, that could be a couple of feet of fairly solid concrete around the base of that wall.

105
00:12:04.725 --> 00:12:12.350
You have to go down below ground level and then through that piece of concrete,

106
00:12:12.870 --> 00:12:29.325
into the the fill or the soil or whatever the thing is that's filled the ground up below the the finished floor level inside the house right we want to get to the lowest level beneath that because that's where the gas could be starting to find its way up from anywhere once it's in there so we need to get

107
00:12:29.925 --> 00:12:55.061
to beneath that where the gas is coming from to then be diverting it away and we are well versed in drilling through all sorts of different wall materials and thicknesses including we do a lot of work in the banking sector and where they have very strong sort of meter meter and a half thick reinforced walls um it is possible with the right equipment to get through those things so yeah just need to listen

108
00:12:56.683 --> 00:13:12.450
So like in a typical scenario where a house would have fairly straightforward foundations and fairly straightforward infill under the foundation or under the floor surface area, this isn't a very big job then.

109
00:13:12.510 --> 00:13:20.253
I guess it's a few hours work for somebody that knows what they're doing, you know, once they've identified what they're doing.

110
00:13:20.833 --> 00:13:26.920
getting on with it, it's a few hours work to actually open this up and get something into that space.

111
00:13:26.940 --> 00:13:27.821
Yeah, precisely.

112
00:13:27.861 --> 00:13:34.669
It's usually completed within a day for a residential property, including the electrical work.

113
00:13:34.690 --> 00:13:38.854
So the sump fans have to be wired into an electrical source.

114
00:13:38.874 --> 00:13:40.737
We usually put an external fuse spur on.

115
00:13:41.477 --> 00:13:42.418
adjacent to the fan.

116
00:13:43.079 --> 00:13:48.945
So that can sometimes take the longest part as well, finding where the nearest electrics are and how to get that route out.

117
00:13:49.025 --> 00:13:52.088
But we as a company offer the whole package.

118
00:13:52.108 --> 00:13:54.871
So it's very straightforward for a customer.

119
00:13:55.832 --> 00:13:57.553
They're not having to coordinate

120
00:13:58.214 --> 00:13:59.976
six different trades to come and do something.

121
00:13:59.996 --> 00:14:02.018
They're not having to leave their property.

122
00:14:03.099 --> 00:14:14.312
They might not want to be there during the day whilst we are drilling because the drilling can be quite noisy, but they don't have to decamp from their house whilst the work's going on.

123
00:14:14.332 --> 00:14:17.395
It's not going to create a lot of dust in the house or anything like that.

124
00:14:17.755 --> 00:14:20.278
It's fairly minor building works in the Great Skins.

125
00:14:20.658 --> 00:14:30.331
I was going to say from your company's perspective, you've got electrical trades within the organisation because you were saying, you know, it takes half a day.

126
00:14:30.351 --> 00:14:35.577
I was going to say the longest part would probably be waiting for an electrician to be available to come and wire your fan up, right?

127
00:14:35.598 --> 00:14:35.698
Yeah.

128
00:14:36.018 --> 00:14:38.761
Yeah, they're part of our team.

129
00:14:38.981 --> 00:14:45.788
So usually for a straightforward installation, we'll have two engineers coming together, one of whom would be a qualified electrician.

130
00:14:45.888 --> 00:14:49.872
So they work together to get the drilling work done and get the pipe work.

131
00:14:50.032 --> 00:14:51.113
Obviously, the pipe,

132
00:14:51.693 --> 00:15:17.314
work height depends on the height of the building and whether we're having to go above any windows and so that can often require two engineers there for safety reasons and depends if we need access equipment if it's a very tall but you know if it's three stories or above then there might need to be some access equipment being arranged but no it's usually two engineers in a day and then the fan is up and running and doing what it needs to be doing from day one.

133
00:15:19.323 --> 00:15:21.504
How much air is that fan moving out of interest?

134
00:15:21.524 --> 00:15:22.044
Do you know?

135
00:15:22.064 --> 00:15:23.684
Is it quite a lot of air?

136
00:15:23.724 --> 00:15:28.225
I mean, I guess a lot depends on how much air it can pull from a sump.

137
00:15:28.545 --> 00:15:33.627
And that will depend largely on the porosity of the substrate that's there, I guess.

138
00:15:33.687 --> 00:15:38.188
So, but it's moving a fair amount of air, is it?

139
00:15:38.760 --> 00:15:39.080
They are.

140
00:15:39.100 --> 00:15:43.743
So there are different fans that are available depending on how much air you need to move.

141
00:15:44.664 --> 00:15:48.986
In the UK, we're fairly limited on what fans are available to us.

142
00:15:49.046 --> 00:16:01.273
Some other more developed markets do have a wider range of fans that are specifically designed for different porosities of substrates, different pressure fields that you need to try and achieve.

143
00:16:01.774 --> 00:16:04.535
In the UK, we have a good range of fans that we use.

144
00:16:04.555 --> 00:16:07.037
We use the fans from Ray Donneray in the US.

145
00:16:07.957 --> 00:16:12.178
And they don't need to move huge volumes of air to be effective, though.

146
00:16:12.558 --> 00:16:21.421
It's about creating the pressure gradient and that's needed to make sure that you've got a negative pressure in that sump underneath the building.

147
00:16:22.021 --> 00:16:24.622
And is that is that a calculated volume?

148
00:16:24.682 --> 00:16:30.583
Is that something you're deliberately calculating and choosing a fan that's appropriate for that calculation?

149
00:16:30.763 --> 00:16:35.785
Or is it really small fan, small house, big fan, big house kind of a thing?

150
00:16:36.940 --> 00:16:43.643
At this stage in the UK, it is really small house for small property, large fan for large industrial unit where there might be.

151
00:16:44.663 --> 00:16:50.726
So on a residential property, you typically have one sump system, one hole connected to one set of pipework with one fan.

152
00:16:51.246 --> 00:16:56.568
It might be that on a large building, we might need more than one sump, so more than one hole.

153
00:16:56.908 --> 00:16:59.729
but we can connect that pipework up into one fan.

154
00:16:59.769 --> 00:17:04.231
So they share a fan which moves more air, but we're drawing from two areas.

155
00:17:04.431 --> 00:17:06.652
So that might be why we use a larger fan.

156
00:17:06.752 --> 00:17:16.936
We might use a larger fan if we've got also a network of sumps that have been put across the floor, or if we know we're drawing from a big void.

157
00:17:16.976 --> 00:17:22.459
So we've talked already now about drilling under a building and creating a point of low pressure

158
00:17:24.120 --> 00:17:26.363
We're talking about buildings with solid floors there.

159
00:17:27.164 --> 00:17:31.509
We do in the UK also have buildings with suspended floor construction though.

160
00:17:32.670 --> 00:17:35.794
Suspended floor constructions can create more of an issue.

161
00:17:35.834 --> 00:17:41.961
They can be more unpredictable I would say in mitigating those properties than with a solid floor.

162
00:17:44.150 --> 00:17:50.713
Yeah, let's come back to that because I think suspended would be worth spending a bit of time on.

163
00:17:50.733 --> 00:17:58.397
But why are my heads in drilling under foundations and fans going in?

164
00:17:59.898 --> 00:18:01.219
Let's stick there for the moment.

165
00:18:01.500 --> 00:18:02.681
So that's interesting.

166
00:18:02.721 --> 00:18:11.609
So basically, potentially, you could be making calculations on the type of fan that would be the most ideal, but you need a market that supports that.

167
00:18:11.649 --> 00:18:15.653
So effectively, really here, you identify a house with radon

168
00:18:16.313 --> 00:18:30.966
you try and identify if you can the area where it's the highest and you would locate based on accessibility, the right place to drill, some various other terms, where that hole goes.

169
00:18:31.366 --> 00:18:34.589
And effectively, normally one of those is enough.

170
00:18:34.849 --> 00:18:40.234
It's not like you need to put three or four or six around the outside of a property.

171
00:18:40.254 --> 00:18:42.976
You'll generally one will make a big enough difference.

172
00:18:43.216 --> 00:18:47.941
Normally, if we're talking about a residential property, normally one of those systems would be sufficient.

173
00:18:48.262 --> 00:18:51.025
The times when it might not be would be if the property has been extended.

174
00:18:52.166 --> 00:18:59.154
So if it's had a large extension and there's due to the foundation walls, it's effectively compartmentalised.

175
00:18:59.574 --> 00:19:24.463
underground each side of the property if you put a sump on the existing part of the building it may not have any effect on the extension and so you may need to have a second system there often we can cite the systems so we call it a dual spare sump so instead of drilling in horizontally we might do a sort of v-shape and so one spur would go under the extension one under the original part of the building and they can then come together in a single vertical exhaust

176
00:19:25.224 --> 00:19:43.067
um so often we do that the other times where you might need more than one system on a residential property would usually be if the house is very large particularly if it's very long if they're square uniform shape then one sump can usually cover a sufficient radius but if you've got a very long

177
00:19:46.835 --> 00:19:47.055
Yeah.

178
00:19:47.276 --> 00:20:01.549
So I've seen a couple of kind of large, single bungalow style houses where they put two or three of these in, but they've been big, Ardell shaped, sprawling ground floor properties.

179
00:20:01.649 --> 00:20:07.774
And so there's a massive footprint compared to the actual volume of the space, whereas a standard kind of.

180
00:20:08.580 --> 00:20:13.806
I guess, three-bed semi is going to have a relatively small footprint, actually.

181
00:20:13.926 --> 00:20:19.933
So a sump is dealing, respectively, with more of the footprint.

182
00:20:21.094 --> 00:20:22.475
Yeah, really interesting.

183
00:20:23.276 --> 00:20:24.998
And there...

184
00:20:27.238 --> 00:20:33.262
Are there things that you're looking for when it comes for locating where that sump goes?

185
00:20:33.282 --> 00:20:40.386
Are there specific things that you're trying to figure out when you identify a location for one?

186
00:20:41.132 --> 00:20:45.695
So we will always look at the test results that have been obtained by the property owner.

187
00:20:46.156 --> 00:20:52.160
Quite often there is just one result for a ground floor room, a living room, because the guidance is to test a living room and a bedroom.

188
00:20:52.700 --> 00:20:56.443
I mean, if it's a two-story property, that just means that the living room has been tested usually.

189
00:20:57.364 --> 00:21:03.928
When we do our design surveys, we do, in some instances, carry out what we call grab sampling.

190
00:21:04.008 --> 00:21:08.532
So we have some surveying equipment which takes a seven-minute radon grab sample.

191
00:21:09.873 --> 00:21:15.737
And we can use that to paint a picture of how the radon levels change or don't change throughout ground floor rooms.

192
00:21:15.817 --> 00:21:17.418
Is there a particular hotspot in one room?

193
00:21:18.159 --> 00:21:20.040
Is it broadly the same across the whole footprint?

194
00:21:20.461 --> 00:21:25.845
And we would never, ever use that equipment for the purpose of deciding whether you have a radon issue or not.

195
00:21:25.945 --> 00:21:36.513
It's not an instant radon test or an instant radon risk assessment, because the level, the reading that you get from that could be completely different if you came back later that afternoon or the following day.

196
00:21:37.033 --> 00:21:39.194
if everyone's had their windows open or they've had the heating on.

197
00:21:39.775 --> 00:21:49.020
And so we would never rely on a quick grab sample reading for deciding if a property needs mitigation, but it can be helpful to benchmark against a long-term reading.

198
00:21:49.460 --> 00:22:02.068
So let's say the living room's been tested, we know the results on that might be say 400 becquels, we do a grab sample on the day that comes back whatever it might do, we're not really looking at the number, we're just looking at comparative with other rooms.

199
00:22:02.528 --> 00:22:03.809
and take a sample in the other rooms.

200
00:22:04.609 --> 00:22:08.792
So we would usually try and cite the sump system where the radon concentrations are highest.

201
00:22:10.193 --> 00:22:12.654
But there are a lot of other things that come into play as well.

202
00:22:14.215 --> 00:22:20.979
Nobody wants a system on the front of the house, pipework and a fan, advertising they might have a radon issue.

203
00:22:21.919 --> 00:22:22.780
right by their front door.

204
00:22:23.460 --> 00:22:24.000
It doesn't look.

205
00:22:24.160 --> 00:22:30.784
They're not too obtrusive these days, but it's not the prettiest thing to have on the front elevation of your house.

206
00:22:30.824 --> 00:22:35.446
So usually we would be putting it on the rear elevation or a side wall if possible.

207
00:22:36.467 --> 00:22:40.349
Obviously, if it's a terraced property, mid-terrace, we only have two options, front or back.

208
00:22:41.949 --> 00:22:51.272
We would not be putting it if there's near or underneath a bathroom or a kitchen ideally because there's lots more pipework there and services to try and avoid.

209
00:22:53.253 --> 00:22:58.454
We would be running it, we have to think about not only where the sump itself is but where the pipework runs.

210
00:22:59.334 --> 00:23:03.496
So obviously the pipework, we don't want it running in front of windows.

211
00:23:04.156 --> 00:23:07.297
Ideally it looks neatest if the pipe can come out of the ground and go straight up.

212
00:23:08.197 --> 00:23:13.141
So we don't really want to be kinking it around other things, other services that might be on the building.

213
00:23:13.681 --> 00:23:18.845
Obviously, if there's things like people have got security lights or alarm system, we can say, actually, that's right where we want to move.

214
00:23:19.226 --> 00:23:19.746
Run the pipe.

215
00:23:19.846 --> 00:23:21.267
Could you move that over slightly?

216
00:23:21.287 --> 00:23:23.649
And sometimes clients will do that.

217
00:23:24.630 --> 00:23:35.538
But in terms of where we want to put the sump from being the most effective, it's looking at what the radon results are telling us and then combining that with practicalities of where we actually can go.

218
00:23:36.528 --> 00:23:45.814
And it's probably a silly question and one I think I know the answer to, but I think it's the sort of thing that people would be interested to understand.

219
00:23:45.854 --> 00:23:53.178
And that is that there's no other associated issues with the air that you're pulling out from under a house odours.

220
00:23:53.738 --> 00:23:56.060
You know, I don't know, something else.

221
00:23:57.461 --> 00:24:01.583
Really, it's all you're interested in is the fact that that air might contain radon.

222
00:24:01.603 --> 00:24:05.205
Therefore, you don't you don't want to be blowing it straight back in the upstairs bedroom window.

223
00:24:06.578 --> 00:24:06.978
Exactly.

224
00:24:07.078 --> 00:24:18.120
It is also quite humid because it's a soil gas and our soil over here tends to be, apart from this summer, usually the soil over here is quite moist, damp most of the year.

225
00:24:19.120 --> 00:24:21.361
So that's a consideration when we're choosing the fans that we use.

226
00:24:21.381 --> 00:24:26.602
They need to be specific fans that can withstand the high humidities of the soil gas passing through.

227
00:24:27.382 --> 00:24:31.183
So that's why we use specialist radon fans, not just an inline fan.

228
00:24:32.843 --> 00:24:34.743
But no, there's nothing apart from that.

229
00:24:35.244 --> 00:24:37.684
The air that comes out, it's not smelling bad.

230
00:24:37.724 --> 00:24:39.624
It hasn't got other contaminants in.

231
00:24:41.125 --> 00:24:44.705
And it's pretty it's pretty low risk, that air as well, from my understanding.

232
00:24:44.785 --> 00:24:49.366
Once once the radon gas is in the atmosphere, it disperses pretty rapidly.

233
00:24:49.486 --> 00:24:57.088
So you are being very cautious when you terminate it, not near a window or something, because practically,

234
00:24:58.165 --> 00:25:07.368
Even if it was terminated under a window, the chance that the amount of radon that would actually find its way back indoors would be tiny, I would imagine.

235
00:25:07.548 --> 00:25:14.551
So it's best practice to ideally be at least a metre away from any opening door or window, because otherwise you do run the risk of recycling it back in.

236
00:25:14.651 --> 00:25:20.133
And what's coming out the end of that sump discharge pipe is highly concentrated radon.

237
00:25:20.153 --> 00:25:21.913
So remember, that's coming right from the source.

238
00:25:22.353 --> 00:25:27.115
So the levels that are in that air are higher than what you would probably have got in your test in the building.

239
00:25:27.856 --> 00:25:36.406
And we do, with our grab sampler, we do test to prove to householders this is what's coming out and the sump is working and the air is coming out.

240
00:25:36.586 --> 00:25:39.569
And the levels can be astonishingly high coming out.

241
00:25:39.589 --> 00:25:39.930
Really?

242
00:25:40.290 --> 00:25:41.271
That's interesting now.

243
00:25:41.612 --> 00:25:42.333
Right at the top.

244
00:25:42.373 --> 00:25:42.613
Right.

245
00:25:43.313 --> 00:25:47.815
So obviously we have risk assessments in place for our staff when they're installing these and when we're maintaining them.

246
00:25:49.296 --> 00:25:56.259
But you would not want to spend a long time standing at the outlet of the sump, breathing that in if you were doing that day to day.

247
00:25:56.519 --> 00:26:03.262
You also would not want it obviously discharging onto, say, your patio area where we do sometimes see...

248
00:26:04.582 --> 00:26:08.366
contractors in the past have installed what they call a low-level sump outlet.

249
00:26:08.386 --> 00:26:13.050
So rather than taking the sump to the full height of the building, they might have boxed it off and capped it off at low level.

250
00:26:14.652 --> 00:26:20.238
It might be that was done in agreement with a householder at the time who said, oh, that's a side path area, we don't use that.

251
00:26:20.938 --> 00:26:36.148
and we don't spend a lot of time there but someone might in the future buy that property you know decide to put some decking there or a terrace or put the child's playhouse there and actually there's very high levels of radiation being pumped out right beside there so we as a rule of thumb

252
00:26:37.089 --> 00:26:38.949
almost always go to the full height of the building.

253
00:26:39.610 --> 00:26:50.192
But you're right that once it comes out the end of the exhaust pipe work, within about 50 centimetres, the wind's taking it away and it's dissipating to low concentrations.

254
00:26:50.232 --> 00:27:01.334
But because we do have the low air pressure in our buildings, if that was right beside a window and you opened that window and that window was open regularly, you could end up with that negative pressure from within the building.

255
00:27:01.794 --> 00:27:23.971
dragging pulling it back in yeah yeah absolutely i'm out of interest what kind of numbers have you seen measured from the discharge pipes then because you said you know if you might have five or six hundred baccarat inside a property are you seeing levels in the thousands 10 times 10 times that can be coming out in the thousands can be coming out of that that pipe work yeah yeah highly

256
00:27:25.513 --> 00:27:31.636
And again, I'd encourage people to listen to the first one in this series with Jose talking about radon.

257
00:27:32.197 --> 00:27:37.440
We've got no worries about radon getting out of the pipe work on its route to atmosphere.

258
00:27:37.500 --> 00:27:42.342
This is the way radon isotopes break down.

259
00:27:42.863 --> 00:27:48.486
It doesn't make it through fairly rudimentary substances like plastic pipe.

260
00:27:48.586 --> 00:27:50.827
So you're not introducing a risk.

261
00:27:51.883 --> 00:27:53.712
in the route to atmosphere.

262
00:27:53.832 --> 00:27:56.786
It's only at the point that the gas comes out that it's a risk.

263
00:27:57.105 --> 00:27:58.426
provided your pipework is sealed.

264
00:27:58.446 --> 00:28:05.048
And that's why predominantly in the UK, our pipework and our sumps are installed outside externally from the building.

265
00:28:05.749 --> 00:28:11.932
In the US, they do a lot of internal systems because they have a lot of unfinished basements as they call it.

266
00:28:11.972 --> 00:28:16.093
So they can put their sump systems in a basement floor potentially or a system in a basement.

267
00:28:16.413 --> 00:28:19.035
And sometimes they do reach some of their pipework through the building.

268
00:28:19.395 --> 00:28:24.317
They use a different grade plastic and connections for their pipework that is guaranteed to be more

269
00:28:24.818 --> 00:28:32.288
quite radon proof, that's because the pipework's running inside here in the UK and most of Europe, our systems are on the outside of the building.

270
00:28:33.238 --> 00:28:45.168
Yeah, I was talking to a colleague in Canada, and one of the things that they'd done there was that they insisted all new builds had the sump terminating inside the building.

271
00:28:45.188 --> 00:28:48.570
And there's a very good reason for that, actually, because of very cold temperatures.

272
00:28:49.411 --> 00:28:53.654
There is a risk to pipework being on the external part of a building.

273
00:28:53.694 --> 00:28:53.975
Right.

274
00:28:54.015 --> 00:28:56.237
So you can really understand that.

275
00:28:57.217 --> 00:29:06.407
But even if there was no known raid on in the area so that they didn't have to terminate it to roof, they would stub it and cap it at floor level in the house.

276
00:29:06.887 --> 00:29:15.796
And of course, with bad building practices, people would see a stub and assume it was a soil pipe, then figure out it wasn't pretty rapidly.

277
00:29:16.717 --> 00:29:17.878
And they'd leave it open.

278
00:29:17.898 --> 00:29:27.204
And basically, they've had lots of cases where they've found open caps from below the ground terminating on the ground floor in the basement.

279
00:29:27.525 --> 00:29:30.767
Basically, an open tap from under the foundations.

280
00:29:31.107 --> 00:29:36.250
So you've got the barrier sealed to this pipe and literally an open hole.

281
00:29:36.471 --> 00:29:36.891
It's just...

282
00:29:37.451 --> 00:29:38.272
Just a nightmare.

283
00:29:38.592 --> 00:29:41.234
But, you know, actually very effective.

284
00:29:41.294 --> 00:29:49.699
And we did some really interesting studies in Ireland, I know, with internal passive stacks to atmosphere.

285
00:29:50.419 --> 00:30:04.829
And so for listeners, instead of having a pipe with a fan on the outside of the building going in under the foundations or to a pre-installed sump ductwork system, actually using a duct that goes internally like a soil stack would...

286
00:30:05.529 --> 00:30:31.987
to the to the ridge of the roof um and because that's negative pressure obviously the risk of leaking is lower if it does leak it's likely to leak from outside into the pipe work but they found it was a very effective measure actually of of um of mitigating raid on it better than just the just having the the raid on barrier itself and of course needs no maintenance there's no fan or anything in there

287
00:30:32.387 --> 00:30:46.287
to need to work on and no running costs one of the big benefits and i think there will be more research in years to come on passive systems and how they can work um the the slight trepidation in the industry about them is that

288
00:30:47.052 --> 00:30:54.035
when they're working, when the temperature's right, when the wind is blowing the right direction and when the pressure is right, they're working fine.

289
00:30:54.496 --> 00:31:01.799
But at some times of year, when some of those things are off, you can end up with higher levels and the system isn't doing.

290
00:31:01.819 --> 00:31:10.503
And you would have no way of knowing how much of the time the system is doing, what you think it's doing and what you hope it's doing and what it's not.

291
00:31:10.843 --> 00:31:14.685
Whereas with a powered mechanical system, so we call that an active sump system where it's

292
00:31:14.845 --> 00:31:21.228
actively using a fan to discharge the radon, you know that that is running 24-7, doing what you think it should be doing.

293
00:31:21.668 --> 00:31:32.233
So assuming it's drawing power and isn't rattling or making a horrible grinding noise, there's a good chance it's sucking a reasonable volume of air, therefore mostly working.

294
00:31:34.314 --> 00:31:37.116
Do they deteriorate over time, these fans?

295
00:31:37.136 --> 00:31:41.878
They obviously, like all moving parts, have a lifespan to them.

296
00:31:41.898 --> 00:31:42.178
Mm-hmm.

297
00:31:42.960 --> 00:31:43.720
They can do.

298
00:31:43.740 --> 00:31:51.883
So the fans that we use, so we saw some fans from a company called RadonAway in the US that have been making radon fans for over 30 years.

299
00:31:52.723 --> 00:31:59.445
And they are specifically designed for radon, moving radon, so soil gas through them.

300
00:31:59.625 --> 00:32:01.926
The motors are all designed for that.

301
00:32:02.186 --> 00:32:05.847
We've been using them in the UK for about the last eight or nine years.

302
00:32:06.927 --> 00:32:11.249
And we have a very low failure rate on those, very, very minimal.

303
00:32:12.589 --> 00:32:15.651
And in the States, they've been used for three decades.

304
00:32:15.811 --> 00:32:26.958
And I see posts on LinkedIn from counterparts in the US who say, who've been doing this for years and say, oh, I've just gone back to, was asked to go and do an inspection on a house where I could see, oh, there was a house

305
00:32:27.498 --> 00:32:30.439
and it had on the service sticker that it was installed by me 20 years ago.

306
00:32:30.859 --> 00:32:33.760
And it's the first time I've been called out and the fans still running potentially.

307
00:32:34.180 --> 00:32:36.621
So the fans can last.

308
00:32:36.741 --> 00:32:38.822
The ones that we use, they have a five year warranty on them.

309
00:32:39.682 --> 00:32:43.183
And we believe that most of them would last far in excess of that.

310
00:32:43.923 --> 00:32:49.625
And as long as they are kept clean, then they don't require maintenance.

311
00:32:49.665 --> 00:32:50.826
They don't have filters in them.

312
00:32:51.806 --> 00:32:53.687
that need regularly changing.

313
00:32:53.707 --> 00:33:05.716
The only thing that we do is we do recommend that at least once every two years someone does come, isolate the system, take the pipework off either end and just clean out because they are sucking on the ground.

314
00:33:05.776 --> 00:33:11.961
There could be bits of debris that have been drawn up into the fan which ultimately could shorten the lifespan of the fan.

315
00:33:14.763 --> 00:33:19.426
Very occasionally we get call outs from customers who say, I can hear the fan rattling, it's making an awful noise.

316
00:33:20.067 --> 00:33:22.789
Usually that's because something has been sucked up into it.

317
00:33:23.489 --> 00:33:26.031
Quite often a snail shell that's come up.

318
00:33:26.371 --> 00:33:32.235
And then once you turn the fan off, we say, turn the fan off for half an hour or something, all of that debris will fall out.

319
00:33:32.636 --> 00:33:35.838
And then they switch it back on and that's cleared the fault and it's fine.

320
00:33:35.878 --> 00:33:38.820
But obviously long term, you don't want bits rattling around inside the fan.

321
00:33:38.880 --> 00:33:41.682
So people call us if that is an issue.

322
00:33:43.043 --> 00:33:44.674
Do they use much power, those fans?

323
00:33:45.552 --> 00:33:47.993
No, they're relatively low power draw.

324
00:33:49.093 --> 00:34:03.096
We say that in a typical household at the moment, it would be around about £100 a year in terms of energy cost, which to some people that is still a barrier to wanting the system installed, particularly in social housing.

325
00:34:04.076 --> 00:34:15.018
We find that that is some resistance that we come up against, but we have to remind people about the unseen benefits that they're having to their health from the system running.

326
00:34:16.078 --> 00:34:18.240
But no, they're not high powered, they're not noisy systems.

327
00:34:18.260 --> 00:34:20.421
That's the other question that we get asked.

328
00:34:20.601 --> 00:34:21.161
Are they noisy?

329
00:34:22.042 --> 00:34:24.743
No, the fan itself runs very quietly.

330
00:34:25.344 --> 00:34:32.948
Any noise that's associated with the system, a sump system, is usually actually the air movement through the pipework.

331
00:34:33.308 --> 00:34:41.393
And we can't really predict what that's going to be until we've installed it, until we know how porous the ground is underneath that we're drawing from.

332
00:34:42.948 --> 00:34:48.310
The way to mitigate any potential issues with noise is to have the fan as low to the ground as possible.

333
00:34:48.350 --> 00:34:56.674
So the shortest distance of pipe between the sump and the bottom of the fan, because it's that section that you'll get that wind rush noise in if you're going to get it.

334
00:34:57.054 --> 00:34:57.874
Interesting.

335
00:34:59.935 --> 00:35:06.201
And are you having to perform some kind of check on the fan after it's installed to see how much air it's pulling?

336
00:35:06.241 --> 00:35:11.105
And do you then have the option to turn it up and down a little bit to compensate?

337
00:35:11.285 --> 00:35:12.686
Is that what effectively you're doing?

338
00:35:13.026 --> 00:35:14.808
So there are options.

339
00:35:14.928 --> 00:35:17.070
Occasionally we do have a speed controller.

340
00:35:17.090 --> 00:35:24.036
So the fans that we use most often, the redone way fan, the standard one that we call the small fan, that is set at a speed that is...

341
00:35:24.516 --> 00:35:29.923
optimum speed for it to create the amount of pressure gradient that it wants to draw.

342
00:35:31.865 --> 00:35:39.675
We can install a speed controller if we find that it's creating too much noise, something like that, to turn that down slightly.

343
00:35:40.336 --> 00:35:43.039
We always check that we've got good airflow coming through the pipework.

344
00:35:43.459 --> 00:35:43.820
It doesn't

345
00:35:45.261 --> 00:35:47.362
Often it doesn't matter exactly how much air is coming.

346
00:35:47.402 --> 00:35:52.484
As long as you are getting a draw, you are creating a negative pressure and you're drawing the gas away.

347
00:35:53.025 --> 00:35:56.306
Yeah, it's less to do with the volume, more to do with the pressure that's created.

348
00:35:56.326 --> 00:35:59.048
Are you measuring that in any way?

349
00:35:59.068 --> 00:36:04.250
Are you able to see how much pressure you introduce or negative pressure you introduce under a blow?

350
00:36:04.290 --> 00:36:09.133
So we can do so with the grab sample I was talking about earlier that takes the six minute grab sample.

351
00:36:09.153 --> 00:36:11.795
That's also a radon away piece of equipment that comes out of their lab.

352
00:36:12.356 --> 00:36:17.579
And it has a manometer mode on it so you can switch it so it can tell you test pressures.

353
00:36:17.619 --> 00:36:23.784
And it's got just the same little probe that we can put in the pipe and check that you are getting a negative pressure.

354
00:36:24.896 --> 00:36:28.658
And you were saying, I mean, different soils, I can imagine that makes a really big difference.

355
00:36:28.718 --> 00:36:45.447
You know, if it's very non-porous clay type soils, you know, I imagine that's your worst nightmare from the perspective of getting air movement versus sandy, loamy, kind of gravelly based, you know, structures under the buildings.

356
00:36:45.876 --> 00:36:46.817
It absolutely is.

357
00:36:46.897 --> 00:36:54.462
And you can usually hear if the fan is struggling, if it's not much air, you can feel without even going to the extent that you're putting a test on.

358
00:36:54.482 --> 00:36:56.844
You can feel how our engineers install these day in, day out.

359
00:36:56.864 --> 00:37:00.867
They know how much air normally would be coming out of once they've switched it on.

360
00:37:01.267 --> 00:37:11.114
If it feels low, then yes, sometimes we can re-drill, try a slightly different area, try and create a slightly bigger void, maybe to give a bit more air around the fan,

361
00:37:12.894 --> 00:37:22.116
If it comes to the stage where the fans have got thermal overload switches in them, so they would cut off before they got too hot.

362
00:37:23.016 --> 00:37:30.918
But when we go to do a maintenance inspection, occasionally we can think this fan is running a little bit warm, it's under pressure here.

363
00:37:31.478 --> 00:37:34.378
We would always look at what the...

364
00:37:34.458 --> 00:37:37.799
So we always do post-mystication radon testing to check has it actually had an effect.

365
00:37:38.299 --> 00:37:43.667
If it has, if the fan is running slightly warm, we would advise the customer that, OK, you've got a good result here.

366
00:37:43.747 --> 00:37:45.049
It's doing what we need it to do.

367
00:37:45.669 --> 00:37:52.819
But the lifespan of this fan might not be as long as it otherwise would be because it's having to work quite hard to achieve this.

368
00:37:53.908 --> 00:38:07.212
And that's where if we were in another country, like in the States where they have a bigger range of fans, we would potentially move to a different type of fan with a different type of motor that's more designed for low airflow, high pressure suction.

369
00:38:08.173 --> 00:38:20.757
If we get to a situation here where a fan just isn't lasting or it's not producing the results that we want, then we would have to look at a different way of doing mitigation, which could be using positive pressure ventilation.

370
00:38:21.957 --> 00:38:39.790
And most of the time when someone's found high radon, you come in and you install the fan and you switch it on and they do a proper post radon test afterwards, which I'm guessing you always advise post the measures putting in.

371
00:38:41.193 --> 00:38:51.817
What kind of percentage of the time does that single measure sort the problem out mostly for people in that kind of drilling under the ground circumstance?

372
00:38:52.037 --> 00:38:56.699
I would say 95% plus time that it works first time.

373
00:38:56.899 --> 00:39:02.321
We never guarantee, we can't offer a guarantee to say we will take your radar level from X to Y.

374
00:39:03.081 --> 00:39:04.742
And we always design a system.

375
00:39:04.762 --> 00:39:07.224
We never say our system is going to take it for next to one.

376
00:39:07.604 --> 00:39:13.747
We just say we are going to design a system that will have the best possible chance to reduce your radar levels as much as we think is possible.

377
00:39:14.288 --> 00:39:16.609
We don't know what that outcome will be.

378
00:39:17.590 --> 00:39:20.551
The vast majority of times the systems work very well.

379
00:39:20.631 --> 00:39:21.152
Sometimes.

380
00:39:21.892 --> 00:39:24.413
It can be harder to get a building with moderate levels.

381
00:39:24.513 --> 00:39:28.254
So let's say you're starting with a building with 300 becquerels of age, per cubic metre.

382
00:39:28.695 --> 00:39:33.276
It can be harder to get that to under 100 than one that started at 3,000 becquerels.

383
00:39:33.636 --> 00:39:37.898
It doesn't always follow that the higher the starting level, the harder it is to get it down.

384
00:39:38.518 --> 00:39:40.759
You could put a sump in a building with 3,000.

385
00:39:40.839 --> 00:39:48.642
It could be incredibly effective due to the layout of the building, the floor construction, the porosity of the ground, where we've located the fan.

386
00:39:49.142 --> 00:39:51.323
that could have a very positive impact.

387
00:39:51.743 --> 00:39:56.105
Whereas in a building which on paper looks, oh, there's not much to do there.

388
00:39:56.125 --> 00:40:02.328
It needs a little bit of work to get the radon levels down, but it's not as big a distance you're trying to close.

389
00:40:03.488 --> 00:40:04.629
Sometimes that can be harder.

390
00:40:06.221 --> 00:40:11.046
There are things we can do if the radon levels don't come down on that first test.

391
00:40:11.226 --> 00:40:13.548
So it could be changing to a bigger fan.

392
00:40:13.869 --> 00:40:15.971
It could be slightly changing the location of the fan.

393
00:40:17.332 --> 00:40:24.459
It could be adding in positive pressurisation, which I think we're going to speak about later, to enhance the effect of the sump fan.

394
00:40:25.400 --> 00:40:33.004
And there's, yeah, so there's things that we can do and we would never leave a customer high and dry and say, oh, well, we tried and it failed.

395
00:40:33.024 --> 00:40:33.944
Yeah, good luck.

396
00:40:34.244 --> 00:40:35.025
Yeah, good luck.

397
00:40:35.185 --> 00:40:40.227
We, and luckily, fortunately, you know, it's very few and far between where we have customers

398
00:40:41.508 --> 00:40:42.368
we're struggling with.

399
00:40:42.969 --> 00:40:46.810
And we do have one particular customer at the moment with a property that we have tried.

400
00:40:46.850 --> 00:40:52.632
It's a very complicated property with split levels, partly below ground, different tenants in buildings.

401
00:40:54.293 --> 00:41:02.575
And we're trying different things and we've tried putting things on one side of the building and it's sorted out one unit, but then the levels have gone up in another flat.

402
00:41:02.956 --> 00:41:09.598
So we've done something there and then that's ping ponged it back here and it's getting the right combination of systems because it's all to do with air movement.

403
00:41:10.378 --> 00:41:12.139
And it's getting that balance right.

404
00:41:12.639 --> 00:41:23.381
But like you say, like 95% of the time, this is a really, it sounds like it, very straightforward, risk based problem solving exercise.

405
00:41:23.401 --> 00:41:25.822
I mean, you can't you can't guarantee anything in life.

406
00:41:25.862 --> 00:41:27.482
I think most people get that.

407
00:41:27.542 --> 00:41:29.903
And the reality is, is you're you can't.

408
00:41:30.915 --> 00:41:33.619
geologically survey under somebody's house.

409
00:41:33.659 --> 00:41:38.546
You're not bringing sonar radar out and heat maps and X, Y, and Z.

410
00:41:38.566 --> 00:41:41.671
At the end of the day, someone's got high radon in their home.

411
00:41:41.951 --> 00:41:44.335
You identify a good spot to drill a hole.

412
00:41:44.395 --> 00:41:45.997
You drill a hole, put a fan on it.

413
00:41:46.578 --> 00:41:47.219
switch it on.

414
00:41:47.479 --> 00:41:49.621
And most of the time, that's it.

415
00:41:49.781 --> 00:41:50.341
Job done.

416
00:41:50.581 --> 00:41:51.382
You walk away.

417
00:41:52.283 --> 00:41:59.509
And that's a fair, it seems in an afternoon or a morning, mostly that's it.

418
00:42:00.029 --> 00:42:00.770
That work is done.

419
00:42:00.990 --> 00:42:12.499
I think a lot of people will be very relieved to hear that because it's, I think it's one of these things, even if you've heard of radon and radon mitigation, there's a lot of misunderstanding of what's involved here.

420
00:42:12.559 --> 00:42:15.482
And what we're describing here is probably the most,

421
00:42:17.338 --> 00:42:24.482
Effort filled amount of work, drilling holes and digging stuff out and putting fans will come on suspended floors in a second.

422
00:42:24.542 --> 00:42:28.085
But there's really not a lot to this.

423
00:42:28.605 --> 00:42:36.710
And so I'm guessing this isn't this isn't costing people tens of thousands of pounds to sort their house out to get this stuff fixed.

424
00:42:37.602 --> 00:42:52.906
No, it's so for a standard property with, you know, standard wall thicknesses, standard electrics, you're talking about probably today's money around about three thousand to three and a half thousand pounds to have a sump system fully installed and fitted.

425
00:42:53.986 --> 00:42:57.827
I would say on there we're talking about, you know, it's job done where we've done that.

426
00:42:57.887 --> 00:43:02.348
We do always reiterate that it's not like a water leak or a dripping tap.

427
00:43:02.708 --> 00:43:05.591
that you've had a plum around and they fixed it and that's fixed forever.

428
00:43:06.332 --> 00:43:10.076
It is a radon mitigation system is effectively a radon management system.

429
00:43:10.877 --> 00:43:15.882
As long as that fan keeps running and the system is running, it will keep doing what you think it's doing.

430
00:43:15.942 --> 00:43:17.584
But the second that fan stops working...

431
00:43:18.285 --> 00:43:36.784
or someone reverses into the pipe and knocks it off the wall and it's not connected properly anymore then your problem comes back so whilst it is do it once do it properly you do need to there is some element of ongoing maintenance to make sure it remains working and it's not completely fit and forget forever

432
00:43:38.179 --> 00:43:39.481
And how realistic is that?

433
00:43:39.581 --> 00:43:45.006
Because I would imagine you do a good job.

434
00:43:45.346 --> 00:43:46.828
You can't hear the fan.

435
00:43:47.428 --> 00:43:51.452
There's not a blinking light inside the front door that tells you it's running.

436
00:43:53.294 --> 00:43:57.358
It's the kind of thing you probably do fit and forget, I would imagine.

437
00:43:57.818 --> 00:44:02.243
So I imagine it's of a percentage of installs.

438
00:44:03.327 --> 00:44:12.093
I imagine it's a fraction of them have you on a two-yearly calendar notification to come back and service, right?

439
00:44:12.668 --> 00:44:15.369
And you would be right in the residential market.

440
00:44:15.649 --> 00:44:16.709
That would be correct.

441
00:44:16.729 --> 00:44:26.092
Although, you know, that is increasing now, more people, they like to, you know, have and I would say, we'll probably talk later a bit more about testing and monitoring in different ways to do that.

442
00:44:26.393 --> 00:44:35.075
The rise of electronic digital monitors is having a positive impact there because people can see in their home on the smartwatch.

443
00:44:35.115 --> 00:44:35.856
If something changes.

444
00:44:36.856 --> 00:44:42.018
they can see or they can get an alert to say, oh, your radon levels have gone up and that might cause them to go and investigate.

445
00:44:42.338 --> 00:44:44.879
There are things we can put on the pipework.

446
00:44:45.159 --> 00:44:50.101
They're called YouTube manometers, which will give a visual indication as to whether the system is working.

447
00:44:50.141 --> 00:44:51.762
There are alarm systems that can be

448
00:44:52.702 --> 00:45:21.304
attached to them they're not measuring the radon level and alarming if your radon level's high they are alerting to a change in the pressure in the system and i don't think we've ever installed them in a residential property but in commercial sector and a lot of our clients for compliance reasons they want a fail-safe way of knowing whether their systems are working rather than relying on staff that happen to be working on that building going and listening and saying was it still running so that is something that we commonly do in the commercial sector but not so much in domestic

449
00:45:21.957 --> 00:45:27.619
You have very particular obligations as an employer to provide safe workplaces.

450
00:45:27.639 --> 00:45:30.020
So I imagine I can well imagine that being the case.

451
00:45:30.400 --> 00:45:49.946
Interestingly, there was a regulation brought in in Ireland for domestic ventilation systems where every ventilation system that's installed has to have, they call it a control indicator, but effectively it just means a light or some indicator to tell you that the system is not working.

452
00:45:50.998 --> 00:45:53.380
or all working correctly, one of the two.

453
00:45:54.320 --> 00:46:03.747
And in most cases, it just indicates a failure in the fan because often like centralized fans, it's a very similar deal.

454
00:46:03.767 --> 00:46:11.012
Particularly if they're not mechanical ventilation with heat recovery that would need annual kind of servicing or filter changes.

455
00:46:12.032 --> 00:46:14.613
they often are fitted and forgot.

456
00:46:14.933 --> 00:46:29.959
And particularly for vulnerable people or disabled or just normal people that once you can't hear something, like most humans, you forget, it's nice to have something that just alerts you that the fans stop working.

457
00:46:29.999 --> 00:46:33.861
You could imagine something like that for the Radon fans could probably be introduced.

458
00:46:33.901 --> 00:46:39.863
We say, look, if you put this in, it'd be nice to have a little light above your back door that just says it's still working.

459
00:46:40.843 --> 00:46:42.824
So again, it's more commonplace in the States.

460
00:46:42.864 --> 00:46:45.386
They do have panels that will connect up.

461
00:46:45.906 --> 00:46:49.088
It's easier there because, as we said before, a lot of their systems are internal.

462
00:46:49.648 --> 00:46:53.170
And so it's easier to connect from here if our system is outside.

463
00:46:53.530 --> 00:46:58.452
Either you have the light outside where the fan is, which might not be somewhere that you're regularly going and looking at.

464
00:46:58.612 --> 00:47:01.014
If it is down your side alleyway or something in the house.

465
00:47:02.374 --> 00:47:11.658
or it involves a lot of cabling from the fan to somewhere in your property, which adds expense, which a lot of people don't want to fork out for.

466
00:47:11.698 --> 00:47:13.139
So there's a balance.

467
00:47:13.913 --> 00:47:24.962
I can imagine, though, by the time you're spending two or three grand on getting one of these things stuck in, a few hundred quid extra to have a control indicator is probably not a significant extra.

468
00:47:24.982 --> 00:47:31.908
But as you say, if you weren't planning for it and you're already stretched to get this done, every penny counts.

469
00:47:32.449 --> 00:47:33.450
Yeah, really interesting.

470
00:47:33.990 --> 00:47:35.812
It's one of those things, isn't it, that

471
00:47:37.352 --> 00:47:38.973
you can see it's very easy to fix.

472
00:47:39.073 --> 00:47:42.134
Once it's installed, it doesn't affect your day-to-day life.

473
00:47:42.554 --> 00:47:49.496
It clearly sorts in 95% of the cases all your problems out.

474
00:47:50.216 --> 00:48:05.500
It's one of those things that if I was looking at buying a home in an area of high radon, I'd be quite assured if I saw a radon pump outside of a house because I know that person has understood the risk, put one in and mitigated the issue for me.

475
00:48:06.100 --> 00:48:20.851
Yeah, it is an understanding and a communication piece, though, that is still missing in the country where a lot of people who aren't so educated on the subject would see that and they would see that as a blighted property, as a property that's got a problem.

476
00:48:20.891 --> 00:48:23.833
But what they would fail to understand is the property that had a problem.

477
00:48:24.393 --> 00:48:50.974
the problem is now being dealt with whereas the next door property that might be on the market no one's done a test you don't know what you're buying you don't know if it's got high radon levels if it does you're then going to have to sort those out so in my mind yeah a system a property with a mitigation system that's a benefit because it's already been identified and dealt with and you just need to maintain that going forward rather than going into the unknown and you don't know what the radon levels might be and

478
00:48:51.616 --> 00:49:01.361
Yeah, I was trying to think of a property analogy off the top of my head of where a home would have a risk and you would expect to see a mitigation to sort that problem out.

479
00:49:02.341 --> 00:49:04.402
And it wouldn't worry you at all.

480
00:49:04.702 --> 00:49:06.163
You'd think it'd be the same for AIDA.

481
00:49:06.183 --> 00:49:09.505
I can't think one off the top of my head that's quite perfect for it.

482
00:49:09.525 --> 00:49:10.705
I'll have to have a think about that one.

483
00:49:11.906 --> 00:49:14.728
Yeah, the suspended timber floors, that was the interesting one.

484
00:49:14.748 --> 00:49:24.976
So a lot of what we've been talking about here is kind of drilling in under the solid floor subsurfaces, trying to carve out a bit of a void to put something in and suck air out of.

485
00:49:25.697 --> 00:49:35.645
A lot of properties, and I mean a lot of properties, particularly in the UK, of a certain age profile are all suspended timber floors, right?

486
00:49:35.865 --> 00:49:38.367
So you've got a ready-made void there, I guess.

487
00:49:38.387 --> 00:49:39.127
So you'd think...

488
00:49:39.928 --> 00:49:42.049
That makes life very easy, right?

489
00:49:42.089 --> 00:49:43.949
But you'd be wrong.

490
00:49:44.649 --> 00:49:46.290
You would be wrong.

491
00:49:46.470 --> 00:49:57.113
Our surveyors, when they turn up to a property or it's in the property notes that we've had from a customer in advance that it's a suspended floor, they know it's not going to be as straightforward as if it was a solid floor.

492
00:49:58.454 --> 00:50:01.836
because you have got a void running under normally the whole footprint of the building.

493
00:50:02.276 --> 00:50:06.819
Sometimes we have mixed floors and that's when it gets really interesting where you've got part suspended, part solid.

494
00:50:08.260 --> 00:50:11.862
And, you know, they're designed with air bricks from that side.

495
00:50:12.122 --> 00:50:19.246
You're supposed to get through ventilation, cross ventilation, not meant to be any dead spots under the floor, but they usually are.

496
00:50:19.827 --> 00:50:25.730
And quite often the properties with suspended floors and the voids, you know, the radon is building up there.

497
00:50:26.131 --> 00:50:26.471
It's being...

498
00:50:26.891 --> 00:50:48.711
encouraged into there through the low pressure it's building in that void and then it's coming up through the floorboards into the house and when we say about putting a sun under a building that's creating a small contained known size void that we are creating a negative pressure in and sucking out from where you've got a suspended floor potentially under the whole footprint of the building

499
00:50:49.131 --> 00:50:50.832
that can be quite a large area.

500
00:50:52.712 --> 00:50:57.654
Sometimes we will, so it can be more trial and error with a suspended floor property.

501
00:50:59.655 --> 00:51:03.837
It's more common that we might have to come back and try something different than if it was a solid floor.

502
00:51:04.977 --> 00:51:09.739
We're upfront with customers about that and we say, you know, we're going to try this.

503
00:51:10.499 --> 00:51:11.900
This might solve your problem.

504
00:51:12.760 --> 00:51:13.821
There's a slight risk that

505
00:51:14.681 --> 00:51:18.942
either it might not solve it or it might temporarily make it worse, which is sometimes what happens.

506
00:51:19.762 --> 00:51:23.603
Even with us, you know, we've been doing this for years and that can sometimes happen.

507
00:51:23.623 --> 00:51:24.503
You've got a floor void.

508
00:51:24.543 --> 00:51:32.304
Sometimes we say, right, we'll do a what you call a sump system, but we will draw to extract from that void and we see what happens.

509
00:51:33.065 --> 00:51:35.105
And sometimes that can work very effectively.

510
00:51:35.585 --> 00:51:40.146
And what's coming into the void comes out, we vent it away, your levels in your house go down nicely.

511
00:51:41.026 --> 00:51:45.691
Sometimes what ends up happening is we're drawing more from the ground into that void.

512
00:51:46.272 --> 00:51:51.557
Some of it's coming out of our pipe work, but actually more of it ends up coming up through the floors into the building.

513
00:51:51.938 --> 00:51:55.842
So what you've inadvertently done is temporarily increase the radial levels.

514
00:51:56.182 --> 00:51:59.986
That doesn't happen often, but it is a risk if you're drawing from a floor void.

515
00:52:00.767 --> 00:52:02.629
And we're upfront with customers that that can happen.

516
00:52:03.630 --> 00:52:31.318
um yeah i was thinking of the i was just thinking of the the all of the different confounding factors of a suspended timber floor and my head was frying just at the while you were talking just at the thought of it uh because you it's a bit like radon coming into your attic you know it's a it's a it's a very awkward space to deal with under the floor because you're not just dealing with um

517
00:52:33.036 --> 00:52:43.541
Radon gas under there, you're dealing with lots of moisture risk issues, lots of thermal risk issues, lots of complexity on air movement down there.

518
00:52:43.921 --> 00:52:48.423
You know, if you negatively pressurize, just create a negative space of the underfloor.

519
00:52:48.463 --> 00:52:52.005
Effectively, what you're doing is you're sucking warm, moist air from the property.

520
00:52:52.705 --> 00:53:06.694
into under the floor void and that will come with a whole heap of problems all of its own you might get rid of radon but your floors will collapse because they've rotted right like you know you if you positively pressurize it then obviously you're blowing radon in um

521
00:53:08.295 --> 00:53:11.996
Yeah, like you say, hopefully you've got good front to back ventilation.

522
00:53:12.016 --> 00:53:19.438
Hopefully you can flush radon out in a kind of a neutral manner and not have an impact on that space.

523
00:53:19.958 --> 00:53:28.880
Just by the nature of having cold air in a floor void and having warm, buoyant air above it in the house, you're going to create a pressure difference anyway.

524
00:53:28.900 --> 00:53:37.682
That's probably much more exacerbated than a solid floor because there's more likely to be more air paths in a suspended timber floor, especially if it hasn't been sealed.

525
00:53:38.402 --> 00:53:46.029
So I can imagine, and as you rightly pointed out, how many suspended timber floors aren't suspended throughout.

526
00:53:46.089 --> 00:53:48.851
There are whole pockets that are solid, right?

527
00:53:49.571 --> 00:53:52.154
Or split levels or do all sorts of weird stuff.

528
00:53:52.174 --> 00:53:54.115
They're compartmentalized in some way.

529
00:53:54.135 --> 00:53:57.038
Yeah, I can imagine you going...

530
00:54:00.050 --> 00:54:00.531
We do.

531
00:54:00.571 --> 00:54:03.514
And our surveyors come back and they say, oh, this is an interesting one.

532
00:54:03.654 --> 00:54:04.335
What should we try?

533
00:54:04.395 --> 00:54:11.283
And sometimes we will present the customer with, you know, a hit list of we're going to try this first and then we'll see.

534
00:54:11.323 --> 00:54:12.724
And then we might try this and it might.

535
00:54:12.965 --> 00:54:15.147
And sometimes it's as simple as turning the fan the other way up.

536
00:54:15.427 --> 00:54:19.251
So sometimes we will start by extracting from a floor void, drawing it out and then

537
00:54:20.413 --> 00:54:27.862
Sometimes we say that's not working, so the sump fans that we use, we can flip them 180 degrees so they are forcing out under.

538
00:54:28.043 --> 00:54:29.525
That can work.

539
00:54:29.725 --> 00:54:34.331
Sometimes it's a combination, one doing one on one end of the building and another one doing the other side.

540
00:54:35.633 --> 00:54:36.414
It really can be

541
00:54:38.886 --> 00:54:41.148
you know, scratch your head, see what happens, trial and error.

542
00:54:41.288 --> 00:54:42.169
And usually we get there.

543
00:54:42.849 --> 00:54:54.019
Sometimes what we do do, you know, if using the floor void is not working, and sometimes we go straight to this, if it's a similar configuration to, you know, another property that we might have worked on and gone, you know, ultimately none of that worked.

544
00:54:54.639 --> 00:54:55.319
we go under.

545
00:54:56.340 --> 00:54:57.761
We completely ignore the floy void.

546
00:54:57.841 --> 00:54:59.642
We dig down deeper.

547
00:55:00.062 --> 00:55:04.324
So we're underneath, completely under the building and we create a sump lower down.

548
00:55:04.464 --> 00:55:15.811
So before we even getting up to that level, we're going deep, deep down to create a void, you know, a pocket, an air pocket, low pressure where the gas can come and we can vent away from there.

549
00:55:16.451 --> 00:55:21.534
And actually sometimes that is the most effective way and that's the most straightforward solution that we can do.

550
00:55:22.554 --> 00:55:23.695
Yeah, my whole...

551
00:55:24.331 --> 00:55:49.480
head of precautionary principles and unintended consequences is running around with its hair on fire at the moment and i wonder what guidance there is out there official on these types of properties because you're with a solid floor there's very little unintended consequence of drilling a sump other than obviously drilling through something right or cutting through something uh

552
00:55:50.900 --> 00:55:59.173
Maybe the water table is quite high and there's a risk of flooding your sump or something or sucking water into the van.

553
00:55:59.213 --> 00:56:00.956
I bet that's happened on occasion.

554
00:56:00.976 --> 00:56:01.177
Yeah.

555
00:56:01.217 --> 00:56:04.983
Some of those people say the pipe's gurgling and say, oh, it's been recently.

556
00:56:05.003 --> 00:56:05.163
Yeah.

557
00:56:05.867 --> 00:56:20.534
So I think the unintended consequence list is fairly low, I imagine, and probably isolated to the installation itself and the actual sump and the fan.

558
00:56:21.454 --> 00:56:24.336
But when you're dealing with suspended timber floors,

559
00:56:25.803 --> 00:56:31.205
They're a weird halfway house between being the environment of the house as well.

560
00:56:31.406 --> 00:56:44.712
And there's a lot of interaction with condensation and vapor movement and moisture and heat and air tightness and radon and odors and, you know, you name it.

561
00:56:44.792 --> 00:56:45.492
And, you know.

562
00:56:47.033 --> 00:56:54.097
pests and like the list is endless really with suspended timber floors.

563
00:56:54.797 --> 00:57:09.566
So does it become multidisciplinary sometimes when you start looking at suspended floors that you're then having to have or use internal expertise with surveying and understanding moisture risk and things like that?

564
00:57:09.826 --> 00:57:10.606
Yeah, definitely.

565
00:57:10.626 --> 00:57:27.371
And I'd say, so certainly within Property Co, my colleague who I started the business with in 2011, and then our current managing director and surveyor and a lot of our surveying team, they actually come from the, they have a background in property preservation.

566
00:57:27.391 --> 00:57:27.811
Got you.

567
00:57:27.831 --> 00:57:31.812
So they're in that industry, in the damp proofing, the timber treatment.

568
00:57:32.112 --> 00:57:55.660
timber preservation industry, basement waterproofing industry, we have expertise from those sectors and it often follows that quite a few radon companies, radon was seen as an add-on to those sorts of services that companies were offering several years ago, so actually quite a lot of radon specialist companies, they do have those areas of expertise within their staff.

569
00:57:56.260 --> 00:58:01.521
And certainly they come into play when we're doing surveys on suspended floors for all the reasons you've listed.

570
00:58:02.841 --> 00:58:06.382
We do not want to solve one problem and cause a whole host of other problems.

571
00:58:07.222 --> 00:58:10.403
Maybe unlivable, even though it's now the air is nice and safe.

572
00:58:10.863 --> 00:58:14.584
But yeah, the building itself is a hazard and we don't want to end up with that.

573
00:58:14.624 --> 00:58:16.204
So yeah, it all comes into play.

574
00:58:17.404 --> 00:58:22.325
I'd like to borrow your attention for just a moment to discuss ACO, a partner of this podcast.

575
00:58:23.401 --> 00:58:33.049
AECO, an EI company, specialises in pioneering new technologies in fire, carbon monoxide alarms and Internet of Things technology.

576
00:58:34.611 --> 00:58:38.054
Many know them as the go-to company for these products.

577
00:58:38.114 --> 00:58:42.217
In fact, this year they're celebrating 35 years in business.

578
00:58:44.295 --> 00:58:54.161
I particularly know them for their outstanding work in the housing sector with their HomeLink offerings, aiming to solve some of the industry's most serious challenges.

579
00:58:55.061 --> 00:59:12.011
The technology incorporates environmental sensors and a gateway to offer connected home solutions, which has a proven track record in helping landlords reduce operational costs and carbon emissions while improving residents' well-being and safety.

580
00:59:13.814 --> 00:59:23.462
Issues at the heart of the housing sector, like damp and mould, fuel poverty and energy efficiency are all in the crosshairs of ACO.

581
00:59:24.703 --> 00:59:37.353
I've been amazed at how they are innovating here, with a laser focus on unpacking some of the complex nature of these challenges in a way that answers the what next question we so desperately need at the moment.

582
00:59:38.111 --> 00:59:41.593
They have a great network of experts and installers.

583
00:59:41.953 --> 00:59:45.335
If you're in housing, they are definitely worth talking to.

584
00:59:46.416 --> 00:59:49.358
Trusted is an overused word, but not here.

585
00:59:49.898 --> 00:59:53.020
Ask around and ACO are synonymous with it.

586
00:59:53.960 --> 00:59:59.723
Details are in the show notes and at airqualitymatters.net and at ACO.

587
01:00:00.124 --> 01:00:03.546
That's A-I-C-O dot co dot UK.

588
01:00:03.986 --> 01:00:05.647
Now back to the podcast.

589
01:00:06.353 --> 01:00:07.374
I wonder what research has been.

590
01:00:07.394 --> 01:00:08.715
I must look up papers and stuff.

591
01:00:08.755 --> 01:00:13.778
If I find anything, I might just chuck them in the social notes about suspended timber floors because it is an interesting one.

592
01:00:13.818 --> 01:00:20.223
And I'm not sure it's really covered very well in past 2035, which for international listeners is the...

593
01:00:21.301 --> 01:00:27.644
UK's kind of risk approach to retrofit, to altering existing buildings.

594
01:00:27.704 --> 01:00:33.907
And, you know, they would deal with moisture risk and they would deal with things like suspended timber floors and so on.

595
01:00:34.507 --> 01:00:36.928
I think they give a cursory mention to Radon.

596
01:00:37.069 --> 01:00:44.732
But I can't imagine this has been thought about in too much depth because you're really trying to solve.

597
01:00:45.152 --> 01:00:49.995
And it's like, for me, a lot of the challenges we see when we try to

598
01:00:51.226 --> 01:01:09.463
Interact ventilation with things like heating and thermal comfort where there's often contradictory goals at certain points within a season or within seasons that mean that ventilation is being overruled in the wrong direction.

599
01:01:09.907 --> 01:01:16.050
times because of a requirement for thermal comfort or for heat or energy use.

600
01:01:16.451 --> 01:01:34.900
And I imagine this is a similar kind of challenge as there's a balance of risks and a balance of requirements between moisture risk, thermal comfort and radon mitigation in a suspended timber floor environment that just simply isn't there in solid floors.

601
01:01:36.041 --> 01:01:37.862
Yeah, they are a lot more complicated.

602
01:01:38.767 --> 01:01:40.227
Yeah, really interesting.

603
01:01:41.048 --> 01:01:43.008
So you were mentioning your company.

604
01:01:43.028 --> 01:01:47.890
For listeners, what's your company called and what's your involvement with them?

605
01:01:47.910 --> 01:01:50.630
Because you've been doing this now for quite a while.

606
01:01:50.650 --> 01:01:59.213
So we're really interested to hear how you found yourself doing this and what the company does, whether it covers nationally and whether it does other stuff as well.

607
01:01:59.966 --> 01:02:10.108
So I work for Property Co. and I founded that business in 2011 with a colleague specifically to focus on Radon and Radon alone.

608
01:02:10.409 --> 01:02:17.610
It's all we've done for the past 16 years in Property Co. My background is not I am not a surveyor.

609
01:02:17.850 --> 01:02:18.930
I am not a geologist.

610
01:02:19.151 --> 01:02:20.751
I am not a physicist.

611
01:02:21.051 --> 01:02:22.251
I came from a business background.

612
01:02:23.412 --> 01:02:27.012
I left university with a first class honours degree in business marketing.

613
01:02:30.033 --> 01:02:37.437
who did property preservation and timber treatments and all those things and had a small department that was looking at radon.

614
01:02:38.638 --> 01:02:41.419
And I was tasked with growing that division.

615
01:02:42.380 --> 01:02:49.504
Ultimately, a colleague and I decided to part ways with that business and set up Property Co to specialise just on radon in 2011.

616
01:02:49.524 --> 01:02:49.924
So I've been...

617
01:02:52.465 --> 01:03:00.251
I started learning about radon in 2007, so I'm almost in my 20th year of becoming a radon expert.

618
01:03:00.431 --> 01:03:03.474
And, you know, I've learned it as a layman.

619
01:03:03.634 --> 01:03:09.058
I've come from, you know, as a graduate, not in a scientific field or an engineering field or, you know, a surveying field.

620
01:03:09.978 --> 01:03:10.559
So I've learnt it.

621
01:03:10.599 --> 01:03:18.724
So I like to think that I could communicate with people like me, not in a high science way and make the topic understandable.

622
01:03:18.984 --> 01:03:23.407
So my role in Property Co, I no longer own the business.

623
01:03:24.027 --> 01:03:28.090
I sold the business when I started my family, but I'm still involved heavily.

624
01:03:29.791 --> 01:03:34.234
I don't go out doing surveying, I don't do many site visits or things these days.

625
01:03:35.235 --> 01:03:47.765
I am mainly desk-based and I assist our larger corporate clients with their projects and doing business development work and planning their testing programmes.

626
01:03:48.025 --> 01:03:57.212
So we work nationally and we cover everything from testing through to design installation of radon mitigation systems and then

627
01:03:57.592 --> 01:04:00.073
maintenance programmes thereafter.

628
01:04:00.414 --> 01:04:11.939
So a lot of my work is with clients coming to me, be that schools or employers, saying, oh we've just found out we're in a radon risk area, we need to get a risk assessment done, what do we do?

629
01:04:11.999 --> 01:04:20.704
So I'll look at their floor plans of their buildings, advise how many detectors they need, and they can decide whether that's something they want to do themselves, we send the detectors to them.

630
01:04:21.544 --> 01:04:26.287
and they place them or we have a service whereby our staff will go out and do the whole thing for them.

631
01:04:26.327 --> 01:04:32.031
So place the detectors in the correct locations and then go and collect them after three months.

632
01:04:32.552 --> 01:04:41.138
They also help with coordinating our mitigation programmes for our larger clients and putting together quotes for those in conjunction with our surveyors who go out to site.

633
01:04:42.178 --> 01:04:59.223
And a big part of my role growing and, you know, over the years, it's very, depending on work and capacity and what we've got is actually in trying to raise some awareness of radon, more on that side of things and the communication side, because I am a

634
01:04:59.803 --> 01:05:04.124
a big believer in that people don't know what they don't know currently.

635
01:05:05.064 --> 01:05:12.466
And when I speak to people about radon and they say to me, you know, socially, when someone goes, first question nowadays is, oh, have you got kids?

636
01:05:12.506 --> 01:05:14.686
And, oh, what do you do for a job?

637
01:05:15.086 --> 01:05:16.626
And you say, oh, have you heard of radon?

638
01:05:16.786 --> 01:05:19.747
You know, it's never a short conversation when someone asks me what I do for a job.

639
01:05:20.427 --> 01:05:24.468
And then it turns into an education piece and they go home and go, oh, tell them, oh, no, no.

640
01:05:25.749 --> 01:05:34.495
But, you know, I think more people should be aware and I don't think enough is done in the UK to raise awareness, to actively try and raise awareness.

641
01:05:34.535 --> 01:05:42.461
So I was one of the founder members of the UK Radon Association, which is the trade association representing members involved in the industry in the UK.

642
01:05:44.583 --> 01:05:52.427
And part of the association's remit is to try and raise radon awareness through various activities.

643
01:05:52.927 --> 01:06:00.431
And so I, through the Trade Association and through Property Co., we run CPD webinars for professionals.

644
01:06:01.131 --> 01:06:12.057
But we also try and put out information in blogs and all sorts that we can try and do things like this, trying to get the message out to more people who otherwise would not have heard of radon.

645
01:06:12.918 --> 01:06:14.179
Yeah.

646
01:06:14.299 --> 01:06:22.664
If only there was a map that could help you understand whether you were likely to be at risk or not, life would be so much easier, wouldn't it?

647
01:06:22.905 --> 01:06:34.372
I mean, this is this is what I I love and hate about radon in equal measures is that the on ramp for people is just so accessible when it comes to radon.

648
01:06:34.432 --> 01:06:42.057
You can literally put your postcode into a website and it will give you a good indication of whether your home is in an area you might want to be concerned about.

649
01:06:42.861 --> 01:06:57.524
And if you are, or even if you're not, for a price of a cheap, these days, McDonald's out, you can do a test, a family trip to McDonald's.

650
01:06:57.544 --> 01:06:59.424
You can do a test, right?

651
01:06:59.524 --> 01:07:07.606
Like it isn't, it's not like the on-ramp is thousands of quid to figure out whether you really, really have a problem or not.

652
01:07:08.386 --> 01:07:27.375
And, you know, as we discussed with those at length in the previous episode, which I encourage people to listen to, there is no way of knowing, you know, you can be in an area of low radon, high radon, and you've got no idea what level of radon you're going to have in your home, even if your next door neighbor did a test and found a particular result of high or low radon.

653
01:07:27.415 --> 01:07:32.898
It's just one of those quirky risks in life that there is only one way to know.

654
01:07:33.298 --> 01:07:33.978
Do a test.

655
01:07:34.219 --> 01:07:35.819
It's going to cost you 50 quid or so.

656
01:07:35.879 --> 01:07:36.980
It's not a lot of money.

657
01:07:37.720 --> 01:07:39.302
It doesn't require any real effort.

658
01:07:39.542 --> 01:07:53.574
It can turn up in the post, you stick it in your living room and your bedroom for a few months, post it back, and then you know, you know, and if it's, if it's low, maybe think about doing it again in 10 years time, if you've done anything to the property, you know, just to.

659
01:07:53.994 --> 01:08:15.553
double check if it's high then you then you can make the decision whether you want to do something about it or not but at least you're not flying blind and it and it's not like we don't know the risks this stuff causes lung cancer and quite a lot of it so it's not something to take lightly so i i love that about radon but i imagine you find that infuriating as well because you're

660
01:08:18.655 --> 01:08:20.576
And, oh, my God, I've got to do a test.

661
01:08:20.596 --> 01:08:23.157
Like, is that people in white lab coats coming around?

662
01:08:23.197 --> 01:08:27.059
And it cost me that, you know, like, it should be so easy, this conversation.

663
01:08:27.380 --> 01:08:33.643
An even worst case scenario, I think, because you've beautifully laid out in layman's terms in the first part of this conversation.

664
01:08:34.623 --> 01:08:37.384
It's not like we've got to tear your house down, solve the problem.

665
01:08:37.884 --> 01:08:43.885
Like many other problems in the built environment, this is fairly non-structural in that sense.

666
01:08:45.466 --> 01:08:49.607
It's not even if you have got high radon in your home, it's not the end of the world.

667
01:08:50.127 --> 01:08:52.727
You know, this is this and often many governments.

668
01:08:52.767 --> 01:09:00.689
I don't know where you're listening from in the world, listeners, but in many countries, there's even grants to help you pay for this stuff in many cases.

669
01:09:00.809 --> 01:09:02.330
So, you know,

670
01:09:03.450 --> 01:09:04.170
Go do the test.

671
01:09:04.190 --> 01:09:07.131
Well, look on the map first and then go and do the test if you're worried.

672
01:09:07.432 --> 01:09:11.973
So the big problem is that so many people still, they just have never heard of radon.

673
01:09:12.013 --> 01:09:14.634
So they don't know that there's a map that they're meant to be looking at.

674
01:09:14.774 --> 01:09:19.256
And awareness activities in the UK, you know, there is a great map.

675
01:09:19.436 --> 01:09:24.518
The UK is one of the first countries that had and has developed the mapping and it is now postcode specific.

676
01:09:24.558 --> 01:09:26.058
You can search it online, as you said.

677
01:09:26.078 --> 01:09:29.440
And for any listeners who are listening, the website you need to go to is UKradon.org.

678
01:09:30.540 --> 01:09:38.388
which is the UK Health Security Agency website, and you can put in your postcode for free, and it will tell you whether you're in a risk area and how great the risk is.

679
01:09:39.009 --> 01:09:39.930
But that is online.

680
01:09:39.950 --> 01:09:42.012
There's a whole heap of information on there.

681
01:09:42.172 --> 01:09:48.198
But unless that message gets to the man on the street, they don't know that they need...

682
01:09:48.972 --> 01:09:49.732
to know about it.

683
01:09:49.813 --> 01:09:57.617
So there's a lot of work being done in social housing now to get landlords should be doing radon tests when they're in high risk areas.

684
01:09:57.777 --> 01:09:59.998
Part of Awab's law, it is now being included.

685
01:10:00.118 --> 01:10:01.939
It is now being taken a lot more seriously.

686
01:10:02.019 --> 01:10:07.803
We have seen a huge uptick in the number of social housing clients that we have and inquiries coming in from that sector.

687
01:10:08.483 --> 01:10:17.050
There's been a huge uptick in the education sector since there was some enforcement action from the health and safety executive against a school who would fail to do what they needed to do.

688
01:10:17.971 --> 01:10:18.952
That sector is growing.

689
01:10:19.132 --> 01:10:20.293
Workplace compliance is.

690
01:10:20.433 --> 01:10:25.057
But the missing part is the homeowning population of the UK.

691
01:10:25.577 --> 01:10:26.918
how we get the message to them.

692
01:10:28.319 --> 01:10:36.766
The message, quite often at the moment, it comes through when you're buying a house in the conveyancing process, the question is brought up, is it in a radon affected area?

693
01:10:37.146 --> 01:10:38.767
Most people, they've never heard of it.

694
01:10:38.787 --> 01:10:39.888
That's the first they're hearing of it.

695
01:10:39.908 --> 01:10:45.893
And then they go on Google and then they panic and they say, oh, I'm buying a house in an area with radiation.

696
01:10:45.953 --> 01:10:46.954
Do I want to live here?

697
01:10:48.014 --> 01:10:49.676
Oh, and it takes three months to get a test.

698
01:10:49.856 --> 01:10:52.157
Oh, well, I can't do that because I'm meant to be completing next week.

699
01:10:52.218 --> 01:10:52.338
And...

700
01:10:53.018 --> 01:10:54.760
it becomes a big panic at that stage.

701
01:10:55.420 --> 01:11:06.829
We need it to become the same level of awareness as with carbon monoxide, which has, you know, over the last couple of decades, carbon monoxide poisoning awareness of has grown considerably.

702
01:11:06.950 --> 01:11:09.291
Most homes now have a carbon monoxide alarm.

703
01:11:09.712 --> 01:11:10.232
As standard.

704
01:11:10.673 --> 01:11:13.195
It's just one of those things that you have because it makes sense to.

705
01:11:13.975 --> 01:11:19.440
And considerably less people die a year from carbon monoxide poisoning than radon.

706
01:11:20.601 --> 01:11:22.442
lung cancer associated with radon.

707
01:11:22.542 --> 01:11:30.967
So, you know, like this thing is... Statistically, you're much more likely to be affected by radon-induced lung cancer than you are by carbon monoxide poisoning.

708
01:11:31.387 --> 01:11:36.471
And the cost of getting a test, you know, I always equate it with, you know, about £50 a year.

709
01:11:36.511 --> 01:11:43.995
You say it's about the cost of getting the MOT on your car, which you have to do every year to make sure your car is roadworthy and it's safe to be in.

710
01:11:44.616 --> 01:11:47.878
Most people spend a lot longer in their house than they do in their car.

711
01:11:49.001 --> 01:11:52.943
We should be putting, you know, and normally you only need to do one radon test in your house.

712
01:11:53.583 --> 01:11:55.564
Certainly not needing to be testing every year.

713
01:11:56.344 --> 01:11:57.284
So it's a one off cost.

714
01:11:57.364 --> 01:12:04.207
We just need to make people aware that it's something as a matter of course you should be doing in your home to make sure the environment is safe.

715
01:12:06.067 --> 01:12:14.132
I always think of it this way, you know, if you're a smoker, you obviously you understand the risk of lung cancer with smoking.

716
01:12:14.152 --> 01:12:17.915
It's been on the packets of cigarettes for decades.

717
01:12:18.095 --> 01:12:21.017
You know, nobody can say they don't understand the risk.

718
01:12:21.057 --> 01:12:28.282
And we understand all of the challenges of getting off nicotine, you know, and I really feel for people that fight that battle.

719
01:12:28.947 --> 01:12:31.549
I've been there myself many, many, many moons ago.

720
01:12:31.569 --> 01:12:42.318
But many smokers spend half their life stood outside of their own home trying to protect their family from their habit.

721
01:12:42.999 --> 01:12:43.259
Right.

722
01:12:43.299 --> 01:12:51.726
And if I thought that that same risk was still in my home for a second as a result of radon and they could have the same problem.

723
01:12:52.527 --> 01:13:03.016
I know I'm risking myself with smoking just by being in a home, I'd be devastated, you know, that that risk existed for my kids or my family.

724
01:13:03.677 --> 01:13:06.099
So, you know, we should care about this.

725
01:13:06.539 --> 01:13:14.727
And it's just one of those things that you don't see enough marketing on, enough consumer awareness of.

726
01:13:14.907 --> 01:13:17.809
And I do wonder if it's somehow deeply rooted in,

727
01:13:18.630 --> 01:13:23.353
the perceived value of property and whether people just don't want to know.

728
01:13:23.553 --> 01:13:28.097
It's one of those things that you can obfuscate and bury your head in the sand about.

729
01:13:28.217 --> 01:13:34.581
And yeah, because it's a carbon monoxide, there's this risk of you not waking up the next morning, right.

730
01:13:34.621 --> 01:13:36.182
As a risk, it's fairly immediate.

731
01:13:36.242 --> 01:13:37.884
And which means we can put a face,

732
01:13:39.184 --> 01:13:43.107
to that tragedy, right?

733
01:13:43.267 --> 01:13:44.848
And it will appear in the news.

734
01:13:44.908 --> 01:13:54.876
A family will die in a caravan or, you know, an elderly person will die because they've, you know, had a gas stove in the living room that was faulty.

735
01:13:54.936 --> 01:13:58.178
And, you know, there's a face to the tragedy, right?

736
01:13:58.418 --> 01:14:06.125
But I think lung cancer is a faceless tragedy when it comes to unavoidable risk.

737
01:14:06.385 --> 01:14:15.753
And I think that a lot of the statistics around lung cancer, because it's associated with smoking, it's seen as a, well, you brought it on yourself risk, right?

738
01:14:15.793 --> 01:14:17.975
So there isn't that associated risk.

739
01:14:18.816 --> 01:14:20.397
tragedy with it.

740
01:14:20.898 --> 01:14:36.269
But if there were names and faces of families that were destroyed by lung cancer as a result of exposure to radon popping up at the weekend in your evening news, in your local evening news, I think we'd take it a lot more seriously.

741
01:14:36.309 --> 01:14:37.610
But we just don't see it.

742
01:14:37.870 --> 01:14:38.691
That's the problem.

743
01:14:38.891 --> 01:14:40.892
But it's happening every single week.

744
01:14:41.173 --> 01:14:41.593
What is it?

745
01:14:41.693 --> 01:14:43.855
Well over 1,200, 1,300 people.

746
01:14:43.875 --> 01:14:45.716
And we think that's fairly conservative.

747
01:14:45.736 --> 01:14:46.857
The official episode is.

748
01:14:47.257 --> 01:14:52.622
Over 1,100 a year in the UK, lung cancer deaths will be linked with radon.

749
01:14:52.682 --> 01:14:54.144
Yeah, nearly 100 people.

750
01:14:54.244 --> 01:15:05.154
Can you imagine a list of 100 people every weekend in your six o'clock news listing the people that died of lung cancer that week as a result of exposure to radon in their homes?

751
01:15:05.775 --> 01:15:07.316
There'd be a national outcry.

752
01:15:07.736 --> 01:15:11.240
You know, we would be doing something about it, but yet they're silent.

753
01:15:11.280 --> 01:15:12.261
We just don't hear it.

754
01:15:12.770 --> 01:15:14.411
And it's because it's very difficult.

755
01:15:14.451 --> 01:15:21.756
By the time it gets to autopsy stage, you cannot prove that this lung cancer, this tumour was specifically due to radon.

756
01:15:21.796 --> 01:15:23.518
It could have been due to a combination of factors.

757
01:15:23.558 --> 01:15:26.240
It could be radon and smoking together, which quite often it is.

758
01:15:27.881 --> 01:15:30.723
But there is, yeah, it's...

759
01:15:30.743 --> 01:15:36.667
So the 1,100 deaths a year, that is epidemiological studies that nobody is arguing with that.

760
01:15:36.707 --> 01:15:40.430
That is the number of deaths based on the population and the amount of radiation that we have.

761
01:15:40.450 --> 01:15:41.110
Yeah.

762
01:15:41.230 --> 01:15:46.192
that is happening, that it's just not on someone's death certificate, you died because of radon.

763
01:15:47.032 --> 01:15:53.614
But you can, in instances, you can extrapolate and say, well, what else were they exposed to in their lifetime?

764
01:15:53.654 --> 01:16:01.757
My former colleague who I started with a business with, his sister ironically died from what we believe to be radon-induced lung cancer.

765
01:16:01.877 --> 01:16:08.319
She'd had a lifestyle, she had other health issues, which meant she was at home for a lot of her time.

766
01:16:08.919 --> 01:16:20.809
in a room that by the time he learned about radon in his career and started making this his career and tested the property and found out that actually she'd been spending many, many years living in a ground floor room with high concentrations of radon.

767
01:16:20.829 --> 01:16:22.931
You know, the damage is done by then.

768
01:16:23.331 --> 01:16:26.434
You can't undo exposure that you've received.

769
01:16:28.155 --> 01:16:37.221
A lot of the time when people come to us nowadays, it is families with young children who are worried because they say, I don't want my children being exposed to this.

770
01:16:38.042 --> 01:16:44.026
And there is research from Canada, Professor Aaron Gadazi, who would be a great guest for your podcast as well.

771
01:16:45.967 --> 01:16:49.850
He has looked and he says, the younger you start receiving exposure,

772
01:16:50.670 --> 01:16:53.252
the worst because it's cumulative exposure over your lifetime.

773
01:16:53.272 --> 01:16:53.892
Yeah.

774
01:16:53.972 --> 01:16:59.695
So if children are being exposed, they've still got 60, 70 years of exposure on top of that that they're going to get.

775
01:16:59.815 --> 01:17:01.496
So that is the worst case.

776
01:17:01.576 --> 01:17:07.660
Having high levels of exposure in young childhood is not good for their long-term health.

777
01:17:08.400 --> 01:17:16.662
Yeah, and we use this analogy all the time in indoor air quality, but you're going to spend 90% of your life indoors, right?

778
01:17:16.682 --> 01:17:22.124
So our built environment is very important to our long-term exposure to risks like radon.

779
01:17:22.424 --> 01:17:26.245
And I'm a big fan of turning that into age.

780
01:17:26.305 --> 01:17:34.847
So I say if your kids are lucky enough to live to 80 years of age, they will spend 55 years of their life in their own home.

781
01:17:36.008 --> 01:17:45.852
So the home is an unbelievably important part of a child's exposure through their lifetime to something like radon.

782
01:17:45.912 --> 01:17:55.696
And for kids, even worse, because they'd also then spend the rest of their time in school, which is often a ground floor building, which we know schools can be very prone to radon as well.

783
01:17:57.297 --> 01:17:59.838
This stuff really matters, particularly to kids.

784
01:17:59.858 --> 01:18:07.362
You're setting them on a trajectory that worst case scenario, they're being exposed both at home and at school to to raid on.

785
01:18:08.002 --> 01:18:13.425
And one of the interesting things I thought you sent me some information there earlier in the week.

786
01:18:14.385 --> 01:18:28.269
And I've seen this before, actually, in Ireland about changes in maps about, you know, just because your home was in a low level of radon 10 or 15 years ago, the last time you looked at this does not mean that that's the case.

787
01:18:28.309 --> 01:18:29.510
Now, these radon maps.

788
01:18:30.330 --> 01:18:35.853
are a hodgepodge of geological surveys, but also testing results.

789
01:18:35.873 --> 01:18:43.417
So they will change over time, depending on the density of tests that have been carried out over that time in the area.

790
01:18:43.757 --> 01:18:44.657
And you can move.

791
01:18:47.234 --> 01:18:54.745
We often talk about it in percentage terms of, you know, like one to six percent or 10 percent risk of being above a threshold.

792
01:18:55.306 --> 01:19:02.396
But what I found really fascinating, I was talking to somebody about this the other day, like in some areas where it's a high risk of radon.

793
01:19:04.790 --> 01:19:12.192
that's a one in five chance in some circumstances that your home could have high levels of radon in it.

794
01:19:12.833 --> 01:19:15.893
Like that's an extraordinary statistic.

795
01:19:16.354 --> 01:19:24.316
And even if it's lower down the risk, even if it's a 10%, you know, that's a one, like, so out of 10 homes on your street, there's a chance.

796
01:19:24.796 --> 01:19:27.797
And that's how radon, well, I mean, radon is a bizarre gas.

797
01:19:27.837 --> 01:19:28.577
Like you can have...

798
01:19:28.837 --> 01:19:31.219
Five houses with no problem whatsoever.

799
01:19:31.359 --> 01:19:34.382
And then that one house that's just inexplicable.

800
01:19:34.842 --> 01:19:35.022
Yeah.

801
01:19:35.423 --> 01:19:35.663
Right.

802
01:19:35.983 --> 01:19:46.672
But, but that, so I think that statistic lands, it's not like it's, yes, it's blended over a street of 20 houses, but like, it really can be that stark.

803
01:19:46.732 --> 01:19:51.856
You could have 10 houses and you're the unlucky house that has,

804
01:19:52.932 --> 01:20:12.650
800 bacquerels of radon in it and and we're not joking that's that happens over and over again so it really is a lottery so when you look at that map really look at it through that lens when you see a percentage risk of a home or one in whatever risk of the home in on that map really think of it

805
01:20:15.412 --> 01:20:19.715
It's not that that 10% is spread evenly across 10 houses.

806
01:20:19.775 --> 01:20:25.217
It really can be the case that one house is just really high and everybody else is fine.

807
01:20:25.978 --> 01:20:35.583
And what I always want, I always say to people, I say, well, for my house, for the sake of £50, I want to know 100% whether that's my house that's affected or not.

808
01:20:36.837 --> 01:20:42.063
As you know, as much as I like my neighbours, I'm not too bothered about what's happening, you know, what the percentage chance is, what they've got.

809
01:20:42.924 --> 01:20:45.046
I spend time and my family spend time in my house.

810
01:20:45.186 --> 01:20:53.996
So whilst the maps are useful for policymakers and people with large estates for budget change,

811
01:20:54.897 --> 01:21:10.891
requirements and you know how where best to target their resources we will test the properties in the highest risk areas when it's your house and you spend all of your time in one house that's the house that matters to you so i you know i tell people to test is best you know

812
01:21:11.832 --> 01:21:35.032
don't look at look at the map if you want to to get an idea particularly if you're in one of the very high risk um areas but actually we want to know what's going on in our house and if our house is has got potentially cancer causing levels of radiation inside it and for the sake of 50 pounds for peace of mind to know that you don't i think that's a price well worth paying um

813
01:21:35.765 --> 01:21:36.225
Yeah.

814
01:21:36.305 --> 01:21:40.687
And then like all other risks, you can decide what your tolerance of that risk is.

815
01:21:40.767 --> 01:21:41.447
It's up to you.

816
01:21:41.527 --> 01:21:53.010
And we're not here to preach to anybody, but at least start from a place of of knowledge, knowing knowledge, and you can then make that call, you know, for you and your family after that.

817
01:21:53.030 --> 01:21:59.112
And often, you know, and we had this conversation, I remember last week, you know, in many cases.

818
01:21:59.152 --> 01:22:01.453
And, you know, I know this from a ventilation perspective.

819
01:22:02.573 --> 01:22:05.856
We go into homes that have some radon in them, right?

820
01:22:06.257 --> 01:22:08.939
Sometimes over the threshold, sometimes below it.

821
01:22:08.999 --> 01:22:17.466
But we know from experience that somewhere between 50-75% of homes don't have adequate ventilation in them.

822
01:22:18.066 --> 01:22:18.887
And this is a gas.

823
01:22:19.127 --> 01:22:24.692
And dilution is the solution for most gas problems in any space.

824
01:22:25.172 --> 01:22:31.156
So often you can fix some of these problems by fixing ventilation as well.

825
01:22:31.216 --> 01:22:40.261
Like many cases, a home may be massively underventilated and you may have a home with damper mold and condensation problems as a result of that underventilation as well.

826
01:22:40.301 --> 01:22:41.982
So there are co-benefits.

827
01:22:42.562 --> 01:22:44.524
to sorting out ventilation as well.

828
01:22:44.624 --> 01:22:46.826
So there's all sorts of solutions for this.

829
01:22:46.886 --> 01:22:55.454
But when it gets to the point of I have radon in my property, sumps and changing the pressure between

830
01:22:56.656 --> 01:22:58.738
Above and below ground is the key.

831
01:22:59.259 --> 01:23:07.487
But when it comes to ventilation, we can positively pressurise buildings as well to mitigate radon, can't we?

832
01:23:07.587 --> 01:23:14.213
So mostly what we've been talking about here is sucking air out from below ground or below the house level.

833
01:23:14.754 --> 01:23:20.259
But we can do the opposite and increase the pressure in the property, can't we?

834
01:23:20.974 --> 01:23:25.977
Yes, so what we've talked about, you know, some might say that's creating an under pressure under the building.

835
01:23:26.358 --> 01:23:29.059
Now we're talking about creating an over pressure within the building.

836
01:23:29.920 --> 01:23:36.724
And it's, you know, we're introducing a gentle amount of extra air into the building to slightly create a positive pressure in there.

837
01:23:37.165 --> 01:23:42.228
It's not when we start talking about positive pressure to people who aren't in the ventilation industry.

838
01:23:42.468 --> 01:23:50.192
they immediately think about going on an aeroplane and your ears popping because of the pressure in the plane and your packet of crisps blowing up.

839
01:23:50.553 --> 01:23:54.034
We're not talking about those perceptible changes in pressure.

840
01:23:54.435 --> 01:23:59.958
We're talking about ever so slightly raising the pressure so that gas isn't attracted into the building.

841
01:24:01.398 --> 01:24:05.040
We can use this if you've got moderate levels of radon in your building.

842
01:24:05.500 --> 01:24:16.606
So the official guidelines from the UK Health Security Agency tend to say if your levels are above about 300 becquerels in a residential building, always go for a sump option because it's likely to give you a better result.

843
01:24:17.166 --> 01:24:20.528
Moderate levels we can be using, thinking about using positive pressure.

844
01:24:21.468 --> 01:24:23.989
if the building lends itself to that.

845
01:24:24.029 --> 01:24:37.413
So a positive pressure system is installing a special type of fan within the building, quite often in the loft space if you've got a roof void, and that draws extra air in from the building through the natural ventilation that's already in the roof.

846
01:24:37.533 --> 01:24:41.555
We're not usually having to put extra roof vent tiles in or pipework or anything like that.

847
01:24:42.415 --> 01:24:50.258
draws the air in, has filters in it, it can warm the air slightly as well, and then it diffuses it out through a diffuser on your landing ceiling.

848
01:24:50.718 --> 01:24:53.279
So you are replacing the amount of air.

849
01:24:53.359 --> 01:24:56.880
All buildings have natural rates of air exchange in them anyway.

850
01:24:57.020 --> 01:25:03.363
All you are doing is increasing that, so you're putting more air in than is naturally escaping through your building in any given hour.

851
01:25:04.803 --> 01:25:07.024
So the benefits for radon are twofold on that.

852
01:25:07.304 --> 01:25:12.205
A, you're increasing the pressure, so you're inhibiting that advection process of the gas being drawn in.

853
01:25:12.805 --> 01:25:15.686
But also you are diluting what is already there.

854
01:25:16.106 --> 01:25:23.728
So you're replacing air that's come from the soil that's within the building with fresh air that's coming from outside at higher levels.

855
01:25:23.828 --> 01:25:26.248
So it's not going to have radon in that air that's coming in.

856
01:25:26.428 --> 01:25:29.429
So the incoming air is cleaner, it's been filtered, it's drier.

857
01:25:31.069 --> 01:25:37.991
And you are then pushing out the potentially stale radon-laden air in the building with that fresh air.

858
01:25:38.691 --> 01:25:39.411
Yeah.

859
01:25:39.671 --> 01:25:51.493
And I think that's good advice for people is that, you know, where you have some levels of radon, like you say, below a certain value, think ventilation as a first course of action.

860
01:25:51.694 --> 01:25:54.714
First, identify whether what you have there is adequate.

861
01:25:54.814 --> 01:25:58.495
If it's not, make it adequate and then maybe retest and see.

862
01:25:59.055 --> 01:26:04.058
Because if you're talking about low levels here, there's a good chance, you know, this is an accumulation thing over your lifetime.

863
01:26:04.078 --> 01:26:09.041
You're not going to suddenly get cancer next week if you don't sort this out quickly.

864
01:26:09.061 --> 01:26:10.001
You've got time.

865
01:26:10.441 --> 01:26:11.122
You've got time.

866
01:26:11.162 --> 01:26:12.022
It's one of those things.

867
01:26:12.082 --> 01:26:13.963
Look, I found radon in my home.

868
01:26:14.383 --> 01:26:17.425
First question is, do I have adequate ventilation in my home?

869
01:26:17.445 --> 01:26:19.246
Because radon ultimately is a gas.

870
01:26:19.406 --> 01:26:20.967
It builds up in a space.

871
01:26:21.307 --> 01:26:24.369
We need to make sure that we're diluting that risk.

872
01:26:24.389 --> 01:26:26.330
So do I have adequate ventilation?

873
01:26:26.370 --> 01:26:28.131
If I don't, can I make it adequate?

874
01:26:28.531 --> 01:26:30.033
Make it adequate test.

875
01:26:30.213 --> 01:26:34.136
Is it has it sorted the problem out or made it worse?

876
01:26:34.897 --> 01:26:39.061
If that's not working, you might speak to a specialist then that might go, well, look, it's low.

877
01:26:39.101 --> 01:26:41.343
Let's try positive input ventilation.

878
01:26:41.363 --> 01:26:46.007
They'll understand the co-risks of PIV in certain circumstances.

879
01:26:46.287 --> 01:26:50.411
And it might be introduced to bring it down or then you might escalate that to.

880
01:26:51.492 --> 01:26:53.232
doing a sump, some description.

881
01:26:53.292 --> 01:26:56.653
But ventilation is definitely something that, and I've seen that work very well.

882
01:26:56.713 --> 01:27:06.536
And like I say, a big frustration for me in many cases is ventilation is so underperforming in many properties that anything's going to build up, frankly, in that property.

883
01:27:06.596 --> 01:27:14.858
Because, you know, most properties on average, let's say are supposed to be achieving half an air change an hour, you know, on average, typically.

884
01:27:16.838 --> 01:27:19.679
You can see properties down a tenth of that.

885
01:27:20.219 --> 01:27:30.105
So is it any wonder that you've got you've got a small amount of radon leaking into the property, which every property does that this room I'm sitting in here is exposed to radon.

886
01:27:30.665 --> 01:27:34.667
It sits anywhere between 75 bacquerels and 350 on the worst possible day.

887
01:27:37.669 --> 01:27:40.592
But on average, it's about 100, 120.

888
01:27:41.433 --> 01:27:42.735
When it rains, it goes away.

889
01:27:42.755 --> 01:27:45.157
When it's sunny and dry and high pressure, it pops up.

890
01:27:45.518 --> 01:27:47.740
You know, it's just one of those quirky gases.

891
01:27:49.302 --> 01:27:51.765
So it's a funny old thing to sort out.

892
01:27:51.805 --> 01:27:53.767
But the only way to know it is do a test.

893
01:27:54.067 --> 01:27:55.089
I mean, on that note...

894
01:27:56.451 --> 01:28:05.816
It must be quite interesting for you to see the advent of electronic sensors as well and an ability now to keep a longitudinal eye on radon.

895
01:28:05.956 --> 01:28:12.299
And we're not saying for a second that it's replacing passive sampling, but it's a fascinating lens.

896
01:28:12.859 --> 01:28:18.182
And again, the reason I know what radon does in this office here is I have a sensor on the shelf that...

897
01:28:18.722 --> 01:28:19.803
monitors the radon.

898
01:28:20.264 --> 01:28:27.471
And you can see it go up and down with the windows open and the sunny weather and the wet weather and the windy weather and all of the things that change it.

899
01:28:27.611 --> 01:28:29.392
But I have a good idea that it's low.

900
01:28:30.241 --> 01:28:52.057
ish on average um and i've done a test obviously a proper test and it corresponds with that it's low it's not of a concern in this property you know so they can be very helpful electronic monitors um we usually recommend that people do passive monitoring with the lab tests the little discs that go back to the lab initially if they're concerned um the

901
01:28:52.918 --> 01:29:01.284
Electronic monitors can be more useful for ongoing monitoring long term, particularly if you're using a sensor that there are many out there that will measure other things as well as radon.

902
01:29:02.004 --> 01:29:07.168
So you might look to get a sensor that measures your general air quality as well, other aspects.

903
01:29:07.348 --> 01:29:16.234
They're very useful once you've got a mitigation system installed to track whether that mitigation system is working and it's working all the time.

904
01:29:17.355 --> 01:29:20.237
We have had a couple of instances where we've had

905
01:29:20.757 --> 01:29:33.988
commercial clients that have had very high radon levels and because they've been so high, they've been told actually under their risk assessment they can't continue to use that part of the workspace until they've proven that the radon levels have come down.

906
01:29:34.008 --> 01:29:45.597
And we've had clients use these alongside, so put in the passive detectors to start their three-month testing and they've used the digital monitors to get an early indication as to, okay, are we going to be okay to reoccupy this space in three months?

907
01:29:46.758 --> 01:29:59.770
And on more than one occasion, we've had where the monitor that we use gives a graphical output and we can see and I can see because clients can invite me to view their data.

908
01:29:59.950 --> 01:30:05.275
And because I'm sad, I sometimes on an evening go and have a look on the app and see what's your radar level doing in your house.

909
01:30:05.335 --> 01:30:07.477
Or if we talk to that, it's usually a business.

910
01:30:08.278 --> 01:30:08.478
And.

911
01:30:09.519 --> 01:30:20.510
And there's one particular one where if we'd waited for the three month post mitigation results to come back, we would have seen a reduction, but not enough of a reduction for them to reoccupy this room.

912
01:30:21.251 --> 01:30:27.617
And what we saw was a pattern whereby in the daytime, the radon levels were beautifully low and then come back.

913
01:30:28.378 --> 01:30:35.625
evening, 6pm every night, they were skyrocketing, shooting up overnight and then plummeting back at about six o'clock the next morning.

914
01:30:35.925 --> 01:30:37.407
And that was happening every single day.

915
01:30:38.388 --> 01:30:41.010
And the reason was we said, you've got, that's not natural.

916
01:30:41.050 --> 01:30:50.139
It's natural to have higher radial levels overnight than in the day, naturally, due to thermal movement and pressure differences and how we heat and ventilate our homes and buildings.

917
01:30:50.539 --> 01:30:51.400
But that was not natural.

918
01:30:51.420 --> 01:30:53.062
That was being mechanically driven by

919
01:30:53.662 --> 01:31:04.053
a setting on their mechanical ventilation system in the building that was going on to a different setting overnight to provide different rates of ventilation and it was exacerbating the problem.

920
01:31:04.433 --> 01:31:11.040
So we said get your ventilation engineer to this building, whatever the setting is in the day, tell it to run at that setting 24-7.

921
01:31:12.281 --> 01:31:13.403
And you can see on this.

922
01:31:13.883 --> 01:31:15.225
We've seen that so often.

923
01:31:15.605 --> 01:31:20.291
We've seen that so often with HVAC systems across all of the air quality things.

924
01:31:20.652 --> 01:31:25.638
People that stay late and all of a sudden start to smell tobacco smoke after six o'clock.

925
01:31:25.939 --> 01:31:26.620
Where's it coming from?

926
01:31:26.640 --> 01:31:27.761
Who's smoking in the building?

927
01:31:27.781 --> 01:31:28.282
And it's not.

928
01:31:28.662 --> 01:31:29.163
It's because...

929
01:31:29.823 --> 01:31:44.315
A building is particularly commercial buildings are often pressurized, you know, are positively pressurized, the HVAC systems, which means when they turn off, that stops and you get ingress of pollution, traffic pollution, smoke from outside and radon would be no different.

930
01:31:45.207 --> 01:31:51.271
You know, in this instance, we could see that they went and switched the settings and then we can see it bubbling along nice and low all through the day.

931
01:31:51.792 --> 01:31:54.634
And then when their three month test comes back, it says, yeah, fine, no problem.

932
01:31:54.754 --> 01:31:59.277
But, you know, if we waited three months and then we'd have gone, oh, why is our sump system not working?

933
01:31:59.757 --> 01:32:04.941
And not knowing that we were actually competing against this other system that was completely overengineered what it was doing.

934
01:32:05.642 --> 01:32:08.744
And so they can be very helpful in those sorts of scenarios.

935
01:32:09.324 --> 01:32:12.606
And they can be unhelpful sometimes with sometimes with.

936
01:32:15.087 --> 01:32:41.315
residential customers who get very obsessed with it we don't, radon exposure it is based as you said on long term averages and long term exposure it will go up and down, you will get peaks like you said, your office there peaks sometimes at 350, we don't want people seeing that once on their digital monitor and going, the sump's broken I must ring Property Co, I need an engineer here tomorrow because it's stopped working, you know

937
01:32:42.216 --> 01:32:48.461
So people have to understand when we when we speak to customers, when we install systems, we do recommend they get these these monitors after.

938
01:32:48.481 --> 01:32:50.503
But we say don't look at averages.

939
01:32:50.623 --> 01:32:54.106
Don't base any decisions based on a single result.

940
01:32:54.146 --> 01:32:54.386
Yeah.

941
01:32:54.566 --> 01:32:58.890
Most of those devices will have month average settings on them, which are perfectly adequate.

942
01:32:58.910 --> 01:33:01.492
They will give you a good sense of roughly where it's at.

943
01:33:02.152 --> 01:33:10.174
Even the weekly averages aren't bad, but I find the month average is the most helpful because usually over a month you'd have had changes in weather and things like that.

944
01:33:10.814 --> 01:33:17.016
And then you can have a look at it and you might understand when radon is particularly high.

945
01:33:17.216 --> 01:33:18.616
It might be interesting.

946
01:33:19.056 --> 01:33:27.058
I think where these electronic sensors really show fascinating applications is for landlords, for people managing radon.

947
01:33:27.698 --> 01:33:44.201
groups of properties or large numbers of social housing or rented properties, commercial properties, because the challenge with radon and radon mitigation, like all risks is you're always being asked, am I doing everything that could be reasonably expected of me with the resources that I have?

948
01:33:44.261 --> 01:33:47.221
And nobody has the resources to fix everything at once.

949
01:33:47.421 --> 01:33:51.942
And what digital visibility gives you is a, is perspective.

950
01:33:52.162 --> 01:33:55.583
It enables you to make informed decisions about what,

951
01:33:56.964 --> 01:34:11.269
property changes, change in tenancy and uses of buildings, all of these things will have impacts, you know, retrofitting and changing and maintaining buildings over time, deteriorations in HVAC systems or ventilation systems over time.

952
01:34:11.710 --> 01:34:17.912
You know, buildings are living organisms that change with the weather and time and who occupies them.

953
01:34:17.972 --> 01:34:18.032
And

954
01:34:18.672 --> 01:34:24.358
Having that kind of digital visibility of it, I think, is a fascinating potential for the future.

955
01:34:24.618 --> 01:34:33.968
Like you say, not at an individual level, you can become overly worried, I think, when you see radon going up and down and it's you can't manage it.

956
01:34:33.988 --> 01:34:40.394
You know, I'm a ventilation geek and I've seen I've seen ventilation go up and down in this office.

957
01:34:41.507 --> 01:34:47.198
And I can do very little about it other than if it gets very high, I can make sure I keep the windows open.

958
01:34:47.238 --> 01:34:54.070
But it's only ever very high in my office because it's baking hot weather is a big high pressure and there's been no rain for weeks.

959
01:34:54.828 --> 01:34:59.752
something about the ground effect just causes radon to pop right under the house.

960
01:35:00.332 --> 01:35:03.215
But then usually the house is well ventilated during those periods.

961
01:35:03.295 --> 01:35:04.075
It's not a problem.

962
01:35:04.316 --> 01:35:10.881
And when it's raining, which is about 95 percent of the winter for me here in Ireland, it's not a problem.

963
01:35:11.661 --> 01:35:14.944
Looking at looking at it now, it's down at 75 degrees.

964
01:35:16.425 --> 01:35:34.135
back or else because it's been pissing with rain for the last four days yeah you know which is which is basically my winter um so yeah it's a it's a funny one but i guess you're interested in that side of it as well that whole electronic side it must must be interesting for you guys

965
01:35:34.555 --> 01:35:57.831
being able to judge the efficacy of an intervention it really is and to see that long term and rather than just a snapshot that you know we might do one post mitigation test three months after and we get that result but actually for the customers who do ask us and invite us to view their data and it is it is helpful and and i think for customers it it makes it

966
01:35:58.976 --> 01:36:12.961
property portfolio managers who are managing hundreds of thousands of properties, being able to see their results, log into a dashboard and see the results at any given time from all their properties, rather than having to send someone out to retrieve a device or go and put it in.

967
01:36:13.661 --> 01:36:14.301
It makes it...

968
01:36:15.667 --> 01:36:19.629
It makes it something that isn't just a one-off that, oh, we've done that radon testing project.

969
01:36:19.649 --> 01:36:21.991
We don't have to think about that for however many years.

970
01:36:22.431 --> 01:36:31.016
It makes it more in line with other compliance things that they're doing regularly and that they get feedback from their fire system or whatever that might be in the building monitoring systems.

971
01:36:31.617 --> 01:36:35.199
It just brings it more into their consciousness.

972
01:36:36.341 --> 01:36:38.842
day to day, that they have that information there.

973
01:36:38.882 --> 01:36:44.743
And as we said, it's not replacing the passive testing for compliance reasons, both for landlords and for employers.

974
01:36:46.024 --> 01:36:52.185
Testing with the passive detectors that go back to a laboratory that's been validated by UK HSA in the UK certainly.

975
01:36:52.865 --> 01:36:57.547
That is the only way that you can, for compliance reasons, show that you've done your testing.

976
01:36:58.547 --> 01:37:10.051
the digital monitoring is an add-on to that and can enhance your risk assessments and can show that you're going further or that you're doing things in between those staged repeat testing programs.

977
01:37:10.831 --> 01:37:11.712
So it's a good thing.

978
01:37:12.292 --> 01:37:21.455
It's a good thing that these monitors are appearing on the likes of Amazon and other online retailers where you can get devices from because someone might just come across one when they're looking for something else.

979
01:37:21.475 --> 01:37:23.116
They're looking to buy a carbon monoxide alarm.

980
01:37:23.496 --> 01:37:26.819
And it shows you in your basket, oh, other customers brought or similar item as this.

981
01:37:26.939 --> 01:37:28.920
And then they might go, oh, what's a radon detector?

982
01:37:28.940 --> 01:37:29.841
Do I need one of those?

983
01:37:30.381 --> 01:37:31.662
And then look into it and say, oh, I did.

984
01:37:31.762 --> 01:37:35.045
And otherwise they would not have known about it.

985
01:37:35.605 --> 01:37:46.673
But I would always advise speaking to a radon specialist like yourself about electronic devices before you buy them, because there are good ones and then there's utter junk on the market.

986
01:37:46.933 --> 01:37:56.817
And you do not want to be making decisions based on your family's health, based on a £20 device that you have no idea whether it's giving you an accurate reading.

987
01:37:56.837 --> 01:37:58.978
Whether it's even measuring radon at all, frankly.

988
01:37:59.078 --> 01:37:59.438
Exactly.

989
01:37:59.538 --> 01:38:03.160
It's like buying a pregnancy test from someone on the street that you don't know.

990
01:38:03.360 --> 01:38:03.820
Oh, is it?

991
01:38:04.420 --> 01:38:06.381
What is this stick that I've got here?

992
01:38:06.421 --> 01:38:07.481
Pregnancy test from Timu.

993
01:38:09.222 --> 01:38:12.264
And I did it at last year's UK radon form that the UK actually do.

994
01:38:12.284 --> 01:38:16.908
They did say there had been someone had rung up about a radon detector that they had bought on Timu.

995
01:38:17.548 --> 01:38:19.170
They apparently are out there in the market.

996
01:38:19.210 --> 01:38:20.691
So I would not advise.

997
01:38:20.811 --> 01:38:24.794
And obviously it had failed all the tests that had been done and it was not accurate.

998
01:38:24.894 --> 01:38:28.356
What I did want to ask you was about the sector in general.

999
01:38:30.018 --> 01:38:32.840
We've talked in detail about kind of the process of...

1000
01:38:33.657 --> 01:38:38.401
of radon mitigation, what does the sector look like in the UK?

1001
01:38:38.421 --> 01:38:48.591
You know, as a person on the street who does test, you know, because you might not get it from a radon company, you might get it direct from the UK HSA, you may just do the test.

1002
01:38:51.855 --> 01:38:54.699
What does the sector look like?

1003
01:38:54.799 --> 01:38:59.384
The skills, the labour, the governance over that?

1004
01:38:59.665 --> 01:39:03.189
Are there organisations that kind of oversee it?

1005
01:39:03.229 --> 01:39:04.631
What does it look like for people?

1006
01:39:05.537 --> 01:39:13.761
So there are two organisations in the UK, membership organisations, voluntary membership organisations for the radon industry.

1007
01:39:14.522 --> 01:39:24.167
So the first thing to say, there is no specific qualification that a radon mitigation engineer needs.

1008
01:39:24.287 --> 01:39:32.511
There is no equivalent surveying qualification as well for the surveyor who's designing a radon mitigation system at the moment in the UK,

1009
01:39:34.932 --> 01:39:37.514
relatively small and a niche business.

1010
01:39:38.235 --> 01:39:49.603
In other parts of the world, in the States, it's a heavily regulated industry where members have to have sat exams and they have to be registered with the state board and all sorts of things to show compliance.

1011
01:39:49.763 --> 01:39:51.024
In the UK, that is not the case.

1012
01:39:53.226 --> 01:39:58.929
The main players in the radon industry are specialists in what they do and have been doing it for many years.

1013
01:39:59.850 --> 01:40:11.238
There are two organisations, and I said there's one, the UK Radon Association, which is a trade association and holds a list of members who have attended meetings of the UK Radon Association, have proven...

1014
01:40:11.658 --> 01:40:29.230
their expertise and knowledge, they've provided references, they've provided details of their experience and training, they've signed up to a code of ethics and they've committed to undergoing ongoing professional development through training to become members of the UK Radion Association.

1015
01:40:31.311 --> 01:40:36.855
And then members of the public can go on the UK Radion Association website and search for a contractor in their area or surveyor.

1016
01:40:37.695 --> 01:40:49.284
There's also a separate organisation called the Radon Council, which does a similar thing and also holds a list of members who have met their standards to become a member.

1017
01:40:49.344 --> 01:40:58.631
So if a member of the public was looking for someone, I would suggest going to those sources to find a suitable contractor or a suitable consultant.

1018
01:40:59.132 --> 01:41:01.096
in the first instance.

1019
01:41:01.416 --> 01:41:05.284
If someone's not on one of those lists, it doesn't mean that they don't know anything about radon.

1020
01:41:05.845 --> 01:41:09.994
They may do, but customers should do their due diligence and find out.

1021
01:41:11.694 --> 01:41:13.695
How long have they been involved in the field?

1022
01:41:14.095 --> 01:41:14.835
In what way?

1023
01:41:14.935 --> 01:41:17.676
So there are more people coming into the industry now.

1024
01:41:17.736 --> 01:41:18.956
It is a growing industry.

1025
01:41:19.957 --> 01:41:33.020
There are people coming in from associated trades, so from the ventilation side, and quite rightly, they are ventilation experts, so they can have a great deal of insight and expertise into specifying positive pressure systems.

1026
01:41:33.340 --> 01:41:37.862
But sometimes we find that if a positive pressure system isn't actually the right system,

1027
01:41:38.742 --> 01:41:44.687
course of action for that building, they can then be stumped because they don't know about designing a sump system and what goes into it.

1028
01:41:44.907 --> 01:41:46.088
We're doing that and drilling a sump.

1029
01:41:46.148 --> 01:41:48.430
Their knowledge ends at PIV.

1030
01:41:49.551 --> 01:41:53.334
There are people coming in from the ground gas industry, so people who've been involved in

1031
01:41:54.395 --> 01:42:15.605
methane place you know installing methane barriers and testing for that and vocs and mainly groundworks on new construction and that is a whole industry in itself and and then they're starting to try and get involved in made on but mitigating an existing building is an entirely different and beasts to installing protection in new builds and

1032
01:42:16.585 --> 01:42:19.928
There are people who've been involved in other compliance aspects.

1033
01:42:19.948 --> 01:42:26.433
So say asbestos, Legionella compliance, thinking, oh, radon's a natural add-on to that.

1034
01:42:26.493 --> 01:42:31.156
And it often is to that business, but they need to have the necessary expertise.

1035
01:42:32.457 --> 01:42:36.080
There is no formal training there at the moment in the UK, so the industry

1036
01:42:36.600 --> 01:42:44.186
is mainly at the moment made up of companies that have maybe splintered off from other companies in the past and people have set up and then they're growing their own businesses.

1037
01:42:44.246 --> 01:42:47.829
And that's how the number of businesses dealing with Radon is growing.

1038
01:42:49.190 --> 01:42:49.871
What's your view?

1039
01:42:49.891 --> 01:42:52.573
I mean, do you, does it need something?

1040
01:42:55.807 --> 01:42:59.230
to be like the US or is that overkill?

1041
01:42:59.650 --> 01:43:01.371
Is it okay the way it is?

1042
01:43:01.391 --> 01:43:13.880
I mean, if you were to oversimplify it and you don't hate me for saying it, but you know how complicated is drilling a hole under a house and sticking and wiring a fan up, right?

1043
01:43:15.181 --> 01:43:17.342
That's a drastic oversimplification.

1044
01:43:17.423 --> 01:43:18.763
I know, but yeah,

1045
01:43:19.924 --> 01:43:33.147
Does it require a two-year course and a qualification and to be on an official government list and spend thousands a year registration fees to be on that list and to kind of go to the extreme?

1046
01:43:34.407 --> 01:43:39.609
Or is it like most things in life, we need something somewhere in between?

1047
01:43:40.089 --> 01:43:41.749
What's your kind of perspective on it?

1048
01:43:41.849 --> 01:43:42.769
I would agree.

1049
01:43:43.009 --> 01:43:44.230
Something somewhere in between.

1050
01:43:44.250 --> 01:43:48.731
The scale of the industry at the moment would not warrant...

1051
01:43:50.091 --> 01:43:55.294
You know, enough companies coming together to need a two year training course or an exam.

1052
01:43:55.895 --> 01:44:11.284
And because the cost of providing that and the cost of getting that legislation, running a system like that, running a scheme, it would be a barrier to entry for anyone doing radon mitigation because it would take them a long time to make that money back.

1053
01:44:11.958 --> 01:44:23.302
And like you saying, most of the industry is made up of companies that have been kicking around for 15, 20 years and know what they're doing by the nature of the length of time in service, if nothing else.

1054
01:44:23.322 --> 01:44:23.602
Right.

1055
01:44:23.702 --> 01:44:29.244
And they come together under these institutions and learn best practice and want to do the right thing.

1056
01:44:29.284 --> 01:44:30.124
So over time.

1057
01:44:31.144 --> 01:44:40.368
And I would imagine as well, many new companies are often splinter off some of these older companies and bring some of that knowledge and work practices with them.

1058
01:44:40.428 --> 01:44:40.688
Right.

1059
01:44:40.728 --> 01:44:44.389
So there's an embedded DNA within a lot of the industry.

1060
01:44:44.409 --> 01:44:46.470
But as you say, it's a small industry.

1061
01:44:47.650 --> 01:44:50.972
But I'm guessing the problem there is, is that it shouldn't be.

1062
01:44:51.192 --> 01:44:56.214
The reason it's a small industry is because we're doing a fraction of the remediation that we should be doing.

1063
01:44:56.454 --> 01:44:56.674
Right.

1064
01:44:57.959 --> 01:45:13.298
So yeah, as awareness grows, as we hope it will, and the market grows, then the radon industry, I would say certainly for us as a company, and I know many of our competitors, we are very busy and we are booked up, you know, three months in advance, our pipeline quite often.

1065
01:45:15.140 --> 01:45:18.441
because we're running at capacity for that.

1066
01:45:19.361 --> 01:45:33.405
We grow, our competitors grow, but there will come a time where there needs to be more people in the industry and whether there will need to be some sort of formal training as a baseline entry requirement in.

1067
01:45:34.105 --> 01:45:54.753
um i don't know um when that would become a requirement certainly in the states no in many states no one can touch a radon system or do something unless they are have been you know approved i don't think in the uk we need to go to that extent because i think in the majority of cases people realize that it is a

1068
01:45:56.255 --> 01:46:03.082
It is a specialism and they're going to specialists with access to specialist products.

1069
01:46:04.203 --> 01:46:07.706
There will always be people who want to do it, either do it themselves.

1070
01:46:07.726 --> 01:46:10.448
There is an argument that you can do your own radon sump.

1071
01:46:11.109 --> 01:46:12.731
Buy the parts, do it yourself.

1072
01:46:12.911 --> 01:46:15.653
And some people, if they're practically minded, that will be fine.

1073
01:46:17.413 --> 01:46:25.836
The problem might come though when you try and sell your house though and at some stage someone says, oh, do you have some sort of certificate to show who installed this and why?

1074
01:46:25.856 --> 01:46:30.517
It might be that someone isn't bothered as long as they can show the radon levels are low, then that's fine.

1075
01:46:31.777 --> 01:46:36.179
But there's considerations that everyone makes based on who they get in.

1076
01:46:36.219 --> 01:46:37.079
Do you get the cheapest?

1077
01:46:37.099 --> 01:46:37.919
Do you get the best?

1078
01:46:37.939 --> 01:46:40.640
Do you get the most experienced contractors?

1079
01:46:41.271 --> 01:46:41.671
Yeah.

1080
01:46:42.272 --> 01:46:50.396
Do you have any sense of what fraction of remediation you're doing compared to what should be being done?

1081
01:46:50.436 --> 01:46:56.579
Like, what's the TMO or total market TMP, total market potential?

1082
01:46:57.019 --> 01:46:58.160
Like, I mean...

1083
01:46:59.040 --> 01:47:07.212
There's potentially, I mean, there are hundreds upon hundreds of thousands of homes that this work needs to be done to, right?

1084
01:47:07.833 --> 01:47:11.037
So I'm guessing you're doing a tiny fraction.

1085
01:47:11.077 --> 01:47:14.662
The sector is doing a tiny fraction of what should be being done.

1086
01:47:15.263 --> 01:47:23.790
And if it was doing it at that scale, the other thing is that there's a massive industry in the maintenance and upkeep of those same systems.

1087
01:47:23.810 --> 01:47:27.113
So it's not a one and done fix.

1088
01:47:27.633 --> 01:47:39.043
So I can imagine this could be a sector that could be 10x the size that it is now and still not be scratching the surface of what should be being done at a national scale.

1089
01:47:39.323 --> 01:47:54.204
It could be, but it's also worth remembering that once we are an island, and I know there is more building going on all the time, but once those buildings, once we have identified the buildings and they've been mitigated, yes, they need ongoing maintenance.

1090
01:47:54.806 --> 01:47:58.047
but they're not all going to need, you know, re-mitigating.

1091
01:47:58.908 --> 01:48:03.410
So what we don't want is, you know, the industry to get to encourage all these people in and say, this is the next big thing.

1092
01:48:03.930 --> 01:48:08.092
Radon is an industry to get into, come and make some money and it to be sort of boom days.

1093
01:48:08.392 --> 01:48:15.575
And then everyone realized, Oh, I mean, it'll be a long time until we've found all the properties that need mitigating and that we have.

1094
01:48:15.755 --> 01:48:20.757
But at some stage, that market then goes, Oh, it's saturated.

1095
01:48:20.837 --> 01:48:20.917
And,

1096
01:48:21.998 --> 01:48:22.639
Now what do we do?

1097
01:48:23.259 --> 01:48:35.190
Yeah, but also like, you know, one of the interesting things about Europe is obviously, what is it, 90% of the buildings that will be around in 2060 already exist today.

1098
01:48:35.311 --> 01:48:39.434
So largely our problem is an existing building problem to sort out.

1099
01:48:40.375 --> 01:48:41.657
But that shouldn't.

1100
01:48:42.943 --> 01:48:51.936
underestimate the challenge of the new build sector as well, because the radon mitigation in most of the new build is preparation for mitigation.

1101
01:48:51.996 --> 01:48:54.220
It's not mitigation in of itself.

1102
01:48:54.320 --> 01:48:57.845
So yes, there might be a sump and a radon barrier, but,

1103
01:48:58.568 --> 01:49:04.311
But they haven't installed those with a pump and a pipe often.

1104
01:49:04.671 --> 01:49:08.053
They've just been prepared for potential radon.

1105
01:49:08.494 --> 01:49:12.236
So, you know, we're building hundreds of thousands of homes every year.

1106
01:49:13.736 --> 01:49:17.398
Those homes, a proportion of those may need some mitigation.

1107
01:49:17.418 --> 01:49:22.761
Now, it should be easier because you should, in theory, have a pipe somewhere terminating on the outside ready to rock and roll.

1108
01:49:23.202 --> 01:49:27.564
But nonetheless, it's still going to need a fan wiring up and ongoing maintenance.

1109
01:49:28.569 --> 01:49:42.230
Yeah, there will always be something, but there won't always be 10 times what we've got today needing to be done because there will become a point, hopefully, when the majority of that has been found and actioned.

1110
01:49:44.294 --> 01:49:47.355
How does it go wrong from a policing perspective?

1111
01:49:47.636 --> 01:50:01.482
I mean, other than making a hames of drilling the holes and bursting through pipes or collapsing walls or doing something horrifying, which I imagine is something you'd be dealing with contractually in the moment with people.

1112
01:50:02.863 --> 01:50:09.946
But failure to actually mitigate or specifying poor products or not achieving results.

1113
01:50:11.365 --> 01:50:12.586
How's that policed?

1114
01:50:12.986 --> 01:50:23.954
And, you know, the hard question always in these kind of ones is, has anybody ever been removed from those lists for not doing the right thing for the public?

1115
01:50:24.034 --> 01:50:26.215
Like, how policed is this?

1116
01:50:26.816 --> 01:50:30.258
And do you see problems there?

1117
01:50:30.318 --> 01:50:38.884
Do we see failures in radon mitigation that shouldn't be happening and a success and or failure then to police that adequately?

1118
01:50:38.904 --> 01:50:39.044
Yeah.

1119
01:50:39.612 --> 01:50:49.937
So sometimes, so we do see issues where sometimes we are called in as specialists and someone says, I've had someone else try to deal with my radon issue and who wasn't a radon specialist.

1120
01:50:49.957 --> 01:50:53.459
It was someone recommended to me in the village who'd done some work for them or whatever.

1121
01:50:53.479 --> 01:50:54.840
And they said, oh, I know a bit about radon.

1122
01:50:55.556 --> 01:51:03.379
And particularly, you know, one I remember about where someone had put an, they'd gone, oh, you've got a thousand becquerels of radon in your building.

1123
01:51:03.839 --> 01:51:04.659
We need to get rid of that.

1124
01:51:04.859 --> 01:51:09.641
And they put a huge powered extract fan in the building to suck out the radon.

1125
01:51:10.061 --> 01:51:14.263
All they did was make the problem twice as bad because they were lowering the pressure and drawing more radon in.

1126
01:51:14.283 --> 01:51:17.184
So they made their radon level 2,000 becquerels rather than 1,000.

1127
01:51:18.164 --> 01:51:24.909
And that was because someone had gone to a non-specialist and then fortunately they then found an actual specialist to advise on it, what they should be doing.

1128
01:51:25.649 --> 01:51:44.141
In terms of people who are radon specialists and maybe not meeting the standards, not doing what they ought to be doing, then yes, there have been instances where members of the public, I sit on the board of the UK Radon Association, and we have had members of the public contact us and say, I had such and such company and I'm not happy because X, Y, Z.

1129
01:51:45.617 --> 01:51:56.685
And the UK Radon Association is a voluntary organisation run by people like me who are in positions, you know, have experience in radon and from a variety of different companies.

1130
01:51:56.725 --> 01:52:01.469
And sometimes, you know, we're looking at our competitors, we're working with our competitors on things for the benefit of the whole industry.

1131
01:52:01.849 --> 01:52:03.950
So the industry doesn't get tainted with

1132
01:52:04.897 --> 01:52:07.018
people thinking, you know, we're a bunch of cowboys.

1133
01:52:07.278 --> 01:52:08.819
And so, yes, we do look into it.

1134
01:52:08.879 --> 01:52:13.000
We speak to the contractor involved, get their side of the story.

1135
01:52:13.161 --> 01:52:27.787
And, you know, there's been a handful of instances where I know there's been some sort of investigation and the trade association has worked with the contractor and the homeowner to come to an amicable arrangement at the end.

1136
01:52:27.847 --> 01:52:32.329
We haven't had to remove anybody from the contractors list.

1137
01:52:33.049 --> 01:52:39.911
Sometimes it's been miscommunication over someone said, we want the sump on that side of the building and they ended up putting it here.

1138
01:52:39.971 --> 01:52:41.431
And why did they why was that changed?

1139
01:52:41.451 --> 01:52:44.052
And there was sometimes there was a good reason for why they put it there.

1140
01:52:44.072 --> 01:52:45.392
It just wasn't communicated.

1141
01:52:46.152 --> 01:52:52.073
And so but, you know, we do take it seriously in the Trade Association and as a company.

1142
01:52:52.093 --> 01:52:54.474
So, you know, we have a good reputation.

1143
01:52:54.534 --> 01:52:55.714
We've been doing this for a long time.

1144
01:52:55.754 --> 01:53:01.336
We wouldn't have the client list that we do have and have a lot of the referrals and, you know, the repeat clients.

1145
01:53:02.996 --> 01:53:25.354
national clients of ours who've been clients for 15 years and you know if we didn't know what we were doing and you know we do we do see you know we have a feel we have a responsibility for people and their health because you know if you were a dodgy plumber who got away with you know putting some pipe work in not quite right on a Friday afternoon and you didn't have the right parts and whatever

1146
01:53:26.074 --> 01:53:32.076
someone, if that was leaking, someone would eventually see a puddle or a drip somewhere and that would alert them.

1147
01:53:32.156 --> 01:53:40.619
We know with radon, no one's going to know unless they're testing, you know, day to day, you don't know whether that's leaking, whether, you know, whether that system's been put in right.

1148
01:53:41.159 --> 01:53:52.403
And morally, we, as you know, certainly speaking on behalf of PropertyCo and speaking on behalf of the UK Radon Association, my colleagues who are from businesses who have been doing this for a long time.

1149
01:53:54.203 --> 01:53:57.466
We feel a sense of responsibility for people and their health.

1150
01:53:58.046 --> 01:53:59.167
They're putting their best in us.

1151
01:53:59.628 --> 01:54:03.251
And I think it's important that we uphold our hand of the bargain.

1152
01:54:04.475 --> 01:54:05.576
But do you know what?

1153
01:54:05.916 --> 01:54:08.957
For me, I find that an assurance.

1154
01:54:09.757 --> 01:54:23.923
And of all the frustrations we've been talking about with radon and it not being recognised, one of the fantastic beauties of radon is that we can test it and it can't be mistaken for anything else.

1155
01:54:24.863 --> 01:54:33.107
So to round the conversation off in a lot of ways, I kind of keep going back to the simplicity of this problem.

1156
01:54:34.662 --> 01:54:36.103
We know where it comes from.

1157
01:54:36.183 --> 01:54:39.565
It doesn't come from anywhere else, largely, right?

1158
01:54:39.585 --> 01:54:45.368
Yes, it comes from the ground, sometimes the water, sometimes building materials, but it is what it is.

1159
01:54:45.448 --> 01:54:46.228
It's radon.

1160
01:54:46.248 --> 01:54:47.989
It appears in the home as a gas.

1161
01:54:48.870 --> 01:54:50.271
We know how to measure it.

1162
01:54:50.351 --> 01:54:52.872
It can't be, we're not using a proxy measurement.

1163
01:54:52.892 --> 01:54:54.513
We're not making assumptions.

1164
01:54:54.593 --> 01:54:59.115
We're not measuring something else and turning it into something else with a complicated formula.

1165
01:54:59.896 --> 01:55:02.277
So we know where it comes from.

1166
01:55:02.477 --> 01:55:03.698
We know how to measure it.

1167
01:55:04.301 --> 01:55:06.942
It's a gas, so we know how to mitigate it.

1168
01:55:06.982 --> 01:55:08.563
It's basic building physics.

1169
01:55:09.803 --> 01:55:23.648
And at the end of the day, when you've had that work done, you can test to see if it works, you know, and in the meantime, whether it did or didn't work, it's not going to be dripping water on your head.

1170
01:55:23.708 --> 01:55:26.349
It's not going to be blowing your house up because of a gas leak.

1171
01:55:26.369 --> 01:55:29.670
You're not going to electrocute as well, unless the wiring to the fan was dodgy.

1172
01:55:30.190 --> 01:55:31.050
Do you know what I mean?

1173
01:55:31.190 --> 01:55:33.872
Like, so nobody's not going to set your house on fire.

1174
01:55:34.492 --> 01:55:36.833
Nothing's going to collapse as a result.

1175
01:55:36.853 --> 01:55:42.075
We're not drilling big enough holes that that side of the house is going to start to become unsettled.

1176
01:55:42.515 --> 01:55:45.897
Like, as a risk thing profile goes...

1177
01:55:46.777 --> 01:55:53.804
And it's very, very low, you know, apart from the caveat of the whole suspended timber floor thing.

1178
01:55:53.824 --> 01:55:55.846
But I think everybody gets what we're talking about there.

1179
01:55:56.146 --> 01:56:06.476
But like this is a really simple done in an afternoon problem solver that doesn't cost the earth.

1180
01:56:07.237 --> 01:56:09.558
It's certainly cheap to test for.

1181
01:56:10.159 --> 01:56:20.605
And if you've got any uncertainty at the end of it, whether it was done right or wrong, then it's another 50 quid test to check, you know, and that's it.

1182
01:56:21.225 --> 01:56:23.947
So for me, I don't understand.

1183
01:56:24.607 --> 01:56:36.494
I struggle to understand why this isn't more commonly understood, deployed and known about as a basic built environment measure that is

1184
01:56:36.934 --> 01:56:44.077
Everybody that's buying a house, everybody that's in a house, any landlord that's managing property and has responsibility for tenants.

1185
01:56:45.377 --> 01:56:56.761
This is just like doing your fire safety tests on your extinguishers, your electrical tests once every couple of years, checking your gas boiler service.

1186
01:56:57.641 --> 01:56:58.461
It's just one of those.

1187
01:56:59.082 --> 01:57:00.462
You own a building.

1188
01:57:00.782 --> 01:57:02.323
It's just one of those things you do.

1189
01:57:03.003 --> 01:57:08.305
you know, and for most people, it won't mean you have to do anything.

1190
01:57:08.585 --> 01:57:14.127
And if you have to do anything for a lot of people, there's a co-benefits of improving ventilation anyway.

1191
01:57:14.707 --> 01:57:20.269
And then worst case scenario, somebody has to turn up for an afternoon and put a pump on.

1192
01:57:20.429 --> 01:57:20.690
Yeah.

1193
01:57:20.730 --> 01:57:21.170
Job done.

1194
01:57:23.182 --> 01:57:27.827
Is that an effective summary of why this should be a no-brainer?

1195
01:57:28.027 --> 01:57:46.003
I hope that this podcast will go some way to convincing people to get out there and search the map, check whether you're in a radon risk area, organise your testing, and know whether you're living or working in a high radon environment because testing is the only way to know and it is important for your health.

1196
01:57:47.370 --> 01:57:50.193
And almost all of us are an employee of somebody.

1197
01:57:52.294 --> 01:57:58.640
And employers have a very specific responsibility to protect us from radon.

1198
01:57:59.000 --> 01:58:05.666
Now, look, if you're working on the 72nd floor of a block in London somewhere, radon's probably not your problem.

1199
01:58:06.207 --> 01:58:06.447
But...

1200
01:58:07.562 --> 01:58:18.047
In many other built environments, schools, offices, shops, warehouses, you know, any built environment that you like to measure, ask your employer.

1201
01:58:18.487 --> 01:58:18.887
Absolutely.

1202
01:58:19.387 --> 01:58:26.951
You can check on the map if your workplace or your kids' education place is in an area of high radon.

1203
01:58:27.806 --> 01:58:28.746
Ask the question.

1204
01:58:29.307 --> 01:58:29.987
It's all you have to do.

1205
01:58:30.027 --> 01:58:31.327
Have you done a radon risk assessment?

1206
01:58:31.347 --> 01:58:32.888
Have you done a radon risk assessment?

1207
01:58:32.908 --> 01:58:33.988
When do you last do it?

1208
01:58:34.268 --> 01:58:44.211
You know, in the same way that you might be interested to know when you walk past the fire extinguishers, when the last time they had that, whether they expired 15 years ago or not, right?

1209
01:58:44.531 --> 01:58:49.753
It's the kind of thing that, you know, as an employee, it makes sense to check.

1210
01:58:49.773 --> 01:58:55.095
Because if I, you know, if I plan to stay there for a few years, you know, I might want to know.

1211
01:58:55.435 --> 01:58:55.595
Yeah.

1212
01:58:55.755 --> 01:58:59.818
And as we said, you can't, once that exposure has occurred, you cannot undo that.

1213
01:59:00.218 --> 01:59:04.781
You can do something about moving forward and preventing yourself getting more exposure.

1214
01:59:04.801 --> 01:59:12.286
So if you've lived in radon affected areas, sometimes people go and they search on the map, they realise the house they're about to move to is in a high risk radon area.

1215
01:59:12.326 --> 01:59:17.569
And then they go, oh, actually, let me put in my childhood home postcode or where have I just moved from?

1216
01:59:18.049 --> 01:59:21.512
And they realise that actually they've been living potentially in high risk areas all their life.

1217
01:59:22.312 --> 01:59:42.850
you can't by that stage you can't do anything about that but you can do something moving forward and once you've got that knowledge it's really important that yeah you act on that and tell other people because just you know as you don't know haven't known maybe until yeah until it's flagged up because you're buying a house a lot of your friends and family might know and it is it's the you know it's a gift that you can give to people that

1218
01:59:43.851 --> 01:59:58.863
education and knowledge that they can do something that because you just it would be awful to have someone go oh i've been diagnosed with lung cancer i've never smoked i don't know what is it and then you go oh i knew about oh i heard about this thing called radon have you never heard of that did you never test your house and

1219
02:00:00.504 --> 02:00:11.609
If nothing else, if you're looking for Christmas presents this year and you're one of those family members that like sending really annoying presents to people, look up your family's postcodes.

1220
02:00:11.769 --> 02:00:15.510
And if they're in a high radon area, send them a test for Christmas.

1221
02:00:15.550 --> 02:00:16.111
Absolutely.

1222
02:00:16.211 --> 02:00:23.614
I have considered offering radon tests at my children's school raffle when they come around and say, can anyone work for a business that can donate raffle prizes?

1223
02:00:23.694 --> 02:00:24.274
I have thought, well.

1224
02:00:24.774 --> 02:00:27.441
We live in a, I'm in Bath, which is a very high risk radon area.

1225
02:00:27.883 --> 02:00:29.788
Would someone like to win some radon detectors?

1226
02:00:30.069 --> 02:00:30.209
Yeah.

1227
02:00:30.488 --> 02:00:31.669
Yeah, yeah, exactly.

1228
02:00:31.789 --> 02:00:35.711
And they're great because, you know, they come in these foil packets and they last a while.

1229
02:00:35.771 --> 02:00:40.813
It's the sort of thing that, you know, they only activate really when you deploy them out.

1230
02:00:40.933 --> 02:00:43.194
So, I mean, yes, they have a shelf life and stuff.

1231
02:00:43.234 --> 02:00:47.156
But, yeah, they are giveable as a present.

1232
02:00:47.256 --> 02:00:51.158
I'm sure I wouldn't be thanked if I sent them around to my fairest family.

1233
02:00:51.178 --> 02:00:51.938
But you never know.

1234
02:00:51.958 --> 02:00:56.120
I think it could be quite a cheeky Christmas present for people.

1235
02:00:56.521 --> 02:00:58.822
Certainly a great moving in present for people.

1236
02:00:58.842 --> 02:00:59.282
Definitely.

1237
02:00:59.857 --> 02:01:00.137
Right.

1238
02:01:00.257 --> 02:01:11.740
You know, you know, anybody that's buying their first home or moving or retrofitting and renovating their home or a tenant are going to be renting a property, you know, off somebody.

1239
02:01:12.540 --> 02:01:13.240
Great present.

1240
02:01:13.361 --> 02:01:14.621
Fifty quid job done.

1241
02:01:15.021 --> 02:01:16.461
You know, I can't think of anything better.

1242
02:01:16.741 --> 02:01:18.902
Rebecca, it's been brilliant talking to you this afternoon.

1243
02:01:19.022 --> 02:01:20.042
Really fascinating.

1244
02:01:20.122 --> 02:01:21.223
And I learned loads, actually.

1245
02:01:21.243 --> 02:01:22.403
I think like a lot of people.

1246
02:01:22.983 --> 02:01:27.386
we throw away terms like remediation and think we know what we're talking about.

1247
02:01:27.406 --> 02:01:40.634
But I think it's really interesting to deep dive into what it actually means and to kind of lay a lot of those fears about how complex and expensive this isn't basically to sort out in most cases.

1248
02:01:41.054 --> 02:01:41.615
Thanks a million.

1249
02:01:41.635 --> 02:01:43.876
Yeah, that was the message we wanted to convey.

1250
02:01:43.896 --> 02:01:45.177
So yeah, I'm glad it's hit home.

1251
02:01:46.178 --> 02:01:46.498
Brilliant.

1252
02:01:46.518 --> 02:01:47.078
Thanks a million.

1253
02:01:47.438 --> 02:01:48.039
Thanks, Simon.

1254
02:01:49.137 --> 02:01:49.758
Thanks for listening.

1255
02:01:49.938 --> 02:01:51.299
Before you go, can I ask a favour?

1256
02:01:51.660 --> 02:01:55.624
If you like this show, please do spread the word and let's keep building this community.

1257
02:01:56.024 --> 02:01:59.148
Like, share, subscribe, give it five stars if you can.

1258
02:01:59.208 --> 02:02:01.210
All that stuff really helps with the reach.

1259
02:02:01.731 --> 02:02:04.213
These shows are not possible without our sponsors.

1260
02:02:04.413 --> 02:02:06.436
So thanks a million to them as always.

1261
02:02:06.816 --> 02:02:07.657
See you again next week.